CRAFT LINE INTERFACE (CLI)
ChromaFlex Chassis – Operation Manual
4-19
ATX Confi dential & Proprietary
Example #1: In this example, the interface #1 of the slot 7 module’s fi ber length is confi gured
with 10 km.
ChromaFlex[slot-7] >FiberLength 1 modify 10
Successful
ChromaFlex[slot-7]
>FiberLength
1
10
km
NOTE: The response of a modifi cation request may either be “Request sent” or “Successful”; in
either case, the user shall retrieve the value to confi rm the new value. You may need to wait for a
few seconds or retrieve a couple times to acquire the new value.
LaserTempAlarm:
displays the alarm status of laser temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of laser temperature as
“MajorLoLo” (e.g. Major alarm with reading below the low low threshold) on channel 1.
ChromaFlex [slot-1] >LaserTempAlarm 1
MajorLoLo
LaserPowerAlarm:
displays the alarm status of laser power (front panel displayed as output power).
Example #1: In this example, the module in slot 1 reports the alarm status of laser power as “MajorLoLo”
(e.g. Major alarm with reading below the low low threshold) on channel 1.
ChromaFlex [slot-1] >LaserPowerAlarm 1
MajorLoLo
LaserRfAlarm
: displays the alarm status of laser RF.
Example #1: In this example, the module in slot 1 reports the alarm status of laser RF as “MajorLoLo”
(e.g. Major alarm with reading below the low low threshold) on channel 1.
ChromaFlex [slot-1] >LaserRfAlarm 1
MajorLoLo
ModuleTempAlarm:
displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as
Normal.
ChromaFlex
[slot-1]
>ModuleTempAlarm
Normal