SNMP ENTERPRISE ATTRIBUTES
ChromaFlex Chassis – Operation Manual
7-9
ATX Confidential & Proprietary
“Module gain control mode.
Note: the write access only apply to modules with changeable gain control.”
::= { innoTransCFlexModuleAnalogEntry 8 }
itModuleAmpPumpPower OBJECT-TYPE
SYNTAX HeTenthdB
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Amplifier pump power in tenth of dBm.”
::= { innoTransCFlexModuleAnalogEntry 9 }
itModuleAmpOutputPower OBJECT-TYPE
SYNTAX HeTenthdB
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Amplifier output power in tenth of dBm.”
::= { innoTransCFlexModuleAnalogEntry 10 }
itModuleOPinPower OBJECT-TYPE
SYNTAX HeTenthdBm
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Optical input power in tenth of dBm.”
::= { innoTransCFlexModuleAnalogEntry 11 }
itModuleOPoutPower OBJECT-TYPE
SYNTAX HeTenthdBm
MAX-ACCESS read-write
STATUS current
DESCRIPTION
“Optical output power in tenth of dBm.”
::= { innoTransCFlexModuleAnalogEntry 12 }
itModuleLaserBiasCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS “milli Amperes”
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Laser bias current in mA.”
::= { innoTransCFlexModuleAnalogEntry 13 }
itModuleRFPower OBJECT-TYPE
SYNTAX HeTenthdBmV
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“RF power in dBmV.”
CHAPTER 7: