SNMP ENTERPRISE ATTRIBUTES
7-10
ChromaFlex Chassis – Operation Manual
ATX Confidential & Proprietary
::= { innoTransCFlexModuleAnalogEntry 14 }
itModuleOpticalPowerdBm OBJECT-TYPE
SYNTAX HeTenthdBm
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Optical power in tenth of dBm.”
::= { innoTransCFlexModuleAnalogEntry 15 }
itModule3V3Power OBJECT-TYPE
SYNTAX HeTenthVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“3.3 v power reading in tenth of volt.”
::= { innoTransCFlexModuleAnalogEntry 16 }
itModuleOpticalModulationIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Optical modulation index.”
::= { innoTransCFlexModuleAnalogEntry 17 }
itModuleGainReserve OBJECT-TYPE
SYNTAX HeTenthdB
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Gain reserve in tenth of dB.”
::= { innoTransCFlexModuleAnalogEntry 18 }
itModuleAttenuation OBJECT-TYPE
SYNTAX HeTenthdB
MAX-ACCESS read-write
STATUS current
DESCRIPTION
“Attenuation settings in tenth of dB.
Note: the write access only apply to modules with changeable attenuation.”
::= { innoTransCFlexModuleAnalogEntry 19 }
itModuleSwitch OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Switch position.”
::= { innoTransCFlexModuleAnalogEntry 20 }
CHAPTER 7: