CRAFT LINE INTERFACE (CLI)
4-14
ChromaFlex Chassis – Operation Manual
ATX Confidential & Proprietary
Example #1: In this example, the module in slot 1 reports the alarm status of optical output power as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
ChromaFlex [slot-1] >OPoutPowerAlarm 1
MajorLoLo
ModuleTempAlarm:
displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as
Normal.
ChromaFlex
[slot-1]
>ModuleTempalarm
Normal
4.1.3.4 Quad Return Receiver (QRRX)
The commands in this section are QRRX specific.
ModuleTemp:
displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4
Centigrade.
ChromaFlex
[slot-1]
>ModuleTemp
+21.4
deg
C
OpticalPowerdBm:
displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power reading on channel 1.
ChromaFlex [slot-1] >OpticalPowerdBm 1
+0.0
dBm
GainControl:
displays the gain control mode setting.
Example #1: In this example, the module in slot 1 reports its gain control mode.
ChromaFlex [slot-1] >GainControl 1
MGC
Modification
: this command supports modification.
Example #1: In this example, the interface #1 of the slot 7 module’s GainControl is configured
with MGC mode.
ChromaFlex[slot-7] >GainControl 1 modify MGC
Successful
ChromaFlex[slot-7]
>GainControl
1
MGC