4.6. SNMP Parameters
MAXNET
®
II – MP3 Active / Passive Chassis – Installation & Operation Manual
4-3
CHAPTER 4: STATUS MONITORING
CHAPTER 4: STATUS MONITORING
Table #6: Administration Level SNMP Parameters
Display Name
Description
Hostname/ Domain Name
Optional fields.
IP Address, Subnet Mask,
Default Gateway
Define the static IP address of the chassis. This address is maintained during power cycles and firmware upgrades. A factory
reset will revert the IP back to 192.168.0.1
DNS Servers
Enter the domain name server to be able to enter textual URLs instead of only IP
addresses.
This affects how you can enter data in some fields below such as NTP server and SMTP server.
NTP Server
Network Time Server (e.g. time.windows.com). If there is no network time server available leave this blank. All times are then
counting from midnight, Jan 1st, 1970 as the start-up time (this is an internet standard).
Time Zone
Only used if NTP server used. Adds local time zone offset to UTC time. e.g. for
Eastern Standard Time Zone, enter ‘UTC+5:0’.
Read-write Community Name
SNMP required variable.
Read-only Community Name
SNMP required variable.
Default Trap Community Name
SNMP required variable.
Trap Recipient List
List up to 10 IP addresses that are to receive SNMP traps
(requires an SNMP trap receiver to interpret these alarm messages).
System Name, Location, Contact
Optional SNMP fields. User can store information about this particular chassis for reference later.
SMTP Server
Outgoing mail server.
If you do not specify a DNS server above, then the server must be entered as an IP address.
Email Recipient List
List up to 5 email addresses that are to receive an email form of the traps.
SMTP Username, Password
If authentication required (ask your IT department), you must enter an email user name and password.
Display Name
Description
HMS MIB Variable
Read Write /
Read Only
Model
ATX model number (note, in empty slots you can enter
passive, dual-passive, or empty to populate the overview
page with passive picture placeholders).
entPhysicalModelName
RO
Description
Description of the module.
entPhysicalDescr
RO
Name
Indicates the slot of the chassis the module is in.
entPhysicalName
RO
Alias
Optional user defined field - added to fifth variable binding
of traps and emails
e.g. set this to “Node 69” for a given Receiver and any
alarms generated by this receiver will have “Node 69” in the
description. Otherwise, it would only contain the IP
address of the chassis, the Model and Name (slot number).
entPhysicalAlias
RW
Manufacturer
ATX
entPhysicalMfgName
RO
Asset I.D
Optional user settable field (suggestions: enter in a custom
serial number or purchase order # for tracking).
entPhysicalAssetID
RW
Serial No
Module’s serial number.
entPhysicalSerialNum
RO
Hardware Rev
Hardware rev of module.
entPhysicalHardwareRev
RO
Firmware Rev
Firmware rev of module.
entPhysicalFirmwareRev
RO
Temperature [C]
Module’s current heatsink temperature.
heCommonTemperature
RO
Alarm Detection Control
detectionEnabled: normal operation, with active alarms
detectionDisabled: used to temporarily disable alarms/traps
from this module
detectionEnabledandRegenerate: enter detectionEnabled
state while regenerating all alarm table entries
heCommonAlarmDetectionControl RW
Fan Unit Status
Alarm status of the fan.
heFanUnitAlarm
RO
Voltage In [Volt]
Measured voltage supplied to the module from the chassis
(nominally 24V).
hePsUnitVoltageIN
RO
Current In [mA]
Current taken from the 24V rail by the module.
hePsUnitCurrentIN
RO
Power In [Watts]
P.S. Voltage * P.S. Current
hePsUnitPowerIN
RO
Table #7: Common Module SNMP Parameters