background image

ATX 

Confidential & Proprietary

OPERATION

1. Operation

1.1.  Operational Details

The  MAXNET  MNRS  RF  switch  provides  redundancy  in  an  RF  amplifier  system.  When  a  failure  occurs  in  the  primary 

amplifier (A) control transfers to a secondary backup amplifier (B). The failure of the amplifier is determined by measuring 

the total composite RF power at the output of the primary (A) amplifier and comparing it to the set RF power threshold level. 

If total composite RF power drops below the threshold level the MNRS transfers to the secondary (B) amplifier to maintain 

normal operation. The switch remains in the B position until the primary (A) amplifier is repaired or replaced and the MNRS 

is reset.

1.2.  Operational Summary

Installation into MAXNET

®

 Chassis:

Install the MNRS into the MAXNET chassis by following the MAXNET RF Detector/Switch and Amplifier Installation sheet 

provided with the unit. 

Threshold Setting:

Front panel 

SET THD

 potentiometer.

Reset:

Front panel momentary push button – press to set primary (A) amplifier active.

Switch Status:

Front panel LED and Relay Contact on rear terminal block.

Power Failure:

Switch Transfers to B position when MNRS power is lost.

NOTE: 

This device is not intended for exact power measurements.

 

It is intended to make a nominal total composite RF power measurement and compare it to a user defined threshold 

 

in order to determine the necessary switch status

          MAXNET

®

 – MNRS Redundant RF Detector/Switch Module – Installation & Operation Manual 

1-1

 

CHAPTER 1:  OPERATION

Figure #1:  MNRS Functional Schematic Diagram

FROM A

RF OUT

FROM B

TO A

RF IN

TO B

RF

DETECTOR

CONTROL

LOGIC

RLY NO

RLY COM

THD

RF

RF (dBmV) THD (dBmV)

(Schematic indicates operation

 when device is not powered)

SET THD

Summary of Contents for MAXNET MNRS

Page 1: ...INSTALLATION OPERATION MANUAL MNRS Redundant RF Detector Switch Module www atxnetworks com www atx com Pat s U S 6 842 348 7 043 236 Cdn 2 404 840 2 404 844 Pat s U S 6 842 348 7 043 236 Cdn 2 404 840 2 404 844 D3 1 CCAP Compliant ...

Page 2: ...tates and or other countries Products or features contained herein may be covered by one or more U S or foreign patents Other non ATX product and company names in this manual are the property of their respective companies Although every effort has been taken to ensure the accuracy of this document it may be necessary without notice to make amendments or correct omissions Specifications subject to ...

Page 3: ...Switch Applications 2 2 3 THRESHOLD LEVEL SETTINGS 3 1 3 1 Coarse Setting 3 9 dB Recommended 3 1 3 2 Fine Setting 3 dB Advanced 3 1 4 DEVICE RESET 4 1 4 1 Redundant Amplifier Configurations 4 1 4 2 RF Detector A B Switch Configurations 4 1 5 SERVICE SUPPORT 5 1 5 1 Contact ATX Networks 5 1 5 2 Warranty Information 5 1 MAXNET MNRS Redundant RF Detector Switch Module Installation Operation Manual i ...

Page 4: ...igures Figures 1 MNRS Functional Schematic Diagram 1 1 2 MNRS Wiring Configuration 2 1 3 MNRS Wiring Configuration 2 2 4 MNRS Front Panel Bar Graph Display 3 1 ii MAXNET MNRS Redundant RF Detector Switch Module Installation Operation Manual ...

Page 5: ...l the MNRS into the MAXNET chassis by following the MAXNET RF Detector Switch and Amplifier Installation sheet provided with the unit Threshold Setting Front panel SET THD potentiometer Reset Front panel momentary push button press to set primary A amplifier active Switch Status Front panel LED and Relay Contact on rear terminal block Power Failure Switch Transfers to B position when MNRS power is...

Page 6: ...ATX Confidential Proprietary CHAPTER 1 OPERATION 1 2 MAXNET MNRS Redundant RF Detector Switch Module Installation Operation Manual This page left intentionally blank ...

Page 7: ...the MAXNET chassis is powered the amplifiers are connected to the MNRS see Figure 2 below review Section 3 for procedures on how to set the threshold level MAXNET MNRS Redundant RF Detector Switch Module Installation Operation Manual 2 1 CHAPTER 2 SET UP Figure 2 MNRS Wiring Configuration ...

Page 8: ...he MAXNET chassis is powered and the MNRS is configured as shown in Figure 3 review Section 3 for procedures on how to set the threshold level 2 2 MAXNET MNRS Redundant RF Detector Switch Module Installation Operation Manual CHAPTER 2 SET UP Figure 3 MNRS Wiring Configuration ...

Page 9: ...than 15 dB below RF Power RF indicator level 3 2 Fine Setting 3 dB Advanced Adjust the SET THD potentiometer fully CCW Press and release the reset RESET push button the B ACTIVE LED should turn off the RF PWR level bar graph should indicate a level between 40 and 70 dBmV Connect a DVM Fluke 87 or equiv between the RF test point black negative lead and the THD red positive lead Adjust the SET THD p...

Page 10: ...ATX Confidential Proprietary CHAPTER 3 THRESHOLD LEVEL SETTINGS 3 2 MAXNET MNRS Redundant RF Detector Switch Module Installation Operation Manual This page left intentionally blank ...

Page 11: ...as been identified and corrected Ensure that the wiring is correct Press and release the reset RESET push button the B ACTIVE LED should turn off the RF PWR level bar graph should indicate a level between 40 and 70 dBmV 4 2 RF Detector A B Switch Configurations No reset required Device returns to primary mode when signal source A returns to a power level above the threshold level MAXNET MNRS Redun...

Page 12: ...ATX Confidential Proprietary CHAPTER 4 DEVICE RESET 4 2 MAXNET MNRS Redundant RF Detector Switch Module Installation Operation Manual This page left intentionally blank ...

Page 13: ... in or out of warranty before returning a failed module to ATX TECHNICAL SUPPORT Tel 289 204 7800 press 1 Toll Free 866 YOUR ATX 866 968 7289 USA Canada only Email support atx com SALES ASSISTANCE Tel 289 204 7800 press 2 Toll Free 866 YOUR ATX 866 968 7289 USA Canada only Email insidesales atx com FOR HELP WITH AN EXISTING ORDER Tel 289 204 7800 press 3 Toll Free 866 YOUR ATX 866 968 7289 USA Can...

Page 14: ... 289 204 7800 Toll Free 866 YOUR ATX 866 968 7289 support atx com 2019 by ATX Networks Corp and its affiliates collectively ATX Networks Corp All rights reserved This material may not be published broadcast rewritten or redistributed Information in this document is subject to change without notice ...