CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual
5-9
Example #1: In this example, the module in slot 1 reports the alarm status of optical receiver power on channel 1
as “MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >opticalpoweralarm 1
MajorLoLo
ModuleTempAlarm:
Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempAlarm
Normal
5.1.2.5 Destacker Proxy
The commands in this section are Destacker Proxy specific.
ModuleTemp:
Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTemp
+21.4 (deg C)
OpticalPowerDbm:
Displays the optical receiver power in dBm.
Example #1: In this example, the module in slot 1 reports its optical receiver power reading as -8.0 dBm.
Transcend [slot-1] >OpticalPowerdBm
-8.0
(dBm)
GainReserve:
Displays the gain reserve in dBm.
Example #1: In this example, the module in slot 1 reports its gain reserve as 6 dBm.
Transcend[slot-1]
>GainReserve
6
(dBm)
Attenuation:
Displays the attenuation in dB.
Example #1: In this example, the module in slot 1 reports its attenuation setting as 0 dB on channel 1.
Transcend [slot-1] >attenuation 1
0.0
(dB)
Mode:
Displays the frequency channel plan mode.
Example #1: In this example, the module in slot 1 reports its frequency channel mode is 2-channel mode.
Transcend [slot-1] >mode
2