CRAFT LINE INTERFACE (CLI)
5-16
TranScend Chassis – Operation Manual
RFPower (dBmV):
[1] -42.1 [2] -99.9
Switch:
Secondary
thresholddBmV (dBmV):
+30.0
Alarm:
Transcend[slot-1]
>alarm
System
PowerAlarm:
Normal
FanAlarm:
Major
Slot 1 (RF-Switch)
SwitchAlarm:
Major
RFPowerAlarm:
[1] MajorLoLo [2] MajorLoLo
ModuleTempAlarm:
Normal
5.1.2.10 AGC EDFA
The AGC EDFA describes in this document applies to the firmware release 1.21 or later.
The commands in this section are
AGC EDFA specific.
OPinPower:
Displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power reading.
Transcend [slot-1] >OPinPower
-99.0
(dBm)
OPoutPower:
Displays the optical output power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical output power reading.
Transcend [slot-1] >OPoutPower
-99.0
(dBm)
GainControl:
Displays the gain control mode.
Example #1: In this example, the module in slot 1 reports its gain control mode.
Transcend [slot-1] >gainControl
AGC
Gain:
Displays the gain reading in dB.
Example #1: In this example, the module in slot 1 reports its gain reading.
CHAPTER 5: