CRAFT LINE INTERFACE (CLI)
5-22
TranScend Chassis – Operation Manual
LockAlarm:
Displays the alarm status of synthesizer lock. It’s an alarm condition when synthesizer loses its lock.
Example #1: In this example, the module in slot 1 reports the alarm status of synthesizer lock as “Major” on
channel 1.
Transcend [slot-1] >LockAlarm 1
Major
ModuleTempAlarm:
Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempalarm
Normal
5.1.2.13 Direct Forward Transmitter (DFB Tx)
The commands in this section are DFB-Tx specific.
ModuleTemp:
Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTempAlarm
+21.4 deg. C
LaserTemp:
Displays the laser temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its laser temperature reading on channel 1.
Transcend [slot-1] >LaserTemp
+23.0 (deg C)
LaserPowerDbm:
Displays the laser power reading in dBm.
Example #1: In this example, the module in slot 1 reports its laser power reading.
Transcend[slot-1]
>LaserPowerDbm
+0.0
dBm
LaserRf:
Displays the RF reading in dB.
Example #1: In this example, the module in slot 1 reports its RF reading.
Transcend[slot-1]
>LaserRf
+0.0
dB
Wavelength:
Displays the laser wavelength in nanometer.
Example #1: In this example, the module in slot 1 reports its laser wavelength.
CHAPTER 5: