USER INTERFACE CROSS REFERENCE
TranScend Chassis – Operation Manual
7-1
USER INTERFACE CROSS REFERENCE
7. User Interface Cross Reference
For user’s convenience, this chapter cross references the managed attributes relating to status and alarms in various user
interfaces. The collective attributes may not be available in all software versions. The general system attributes, for example,
model name, are omitted from these listings. Please refer to the CLI and SNMP Enterprise MIB sections for details.
7.1 System / Chassis Attributes
Front Panel Display CLI
SNMP OID
SNMP Trap ID
Alarm: Pwr Sply
PowerAlarm
.iTTrancendNotification.31
Alarm: Fan
FanAlarm
.iTTrancendNotification.32
Slot
Slot
.innoTransModuleEntry.2
.iTTrancendNotification.33
The “Slot” is a special attribute; there is no direct mapping between CLI and SNMP. “Slot” in CLI provides an inventory
snapshot; while user can extract the slot state and inventory via SNMP.
7.2 High Sensitivity Quad Return Receiver Attributes
Front Panel
Display
CLI
SNMP OID
SNMP Trap ID
Status: Optical
Alarm: Receiver
Power
OpticalPowerAlarm
.iTTrancendNotification.19
Alarm: Module
Temp
ModuleTempAlarm
.iTTrancendNotification.30
Optical: Power
(dBm)
OpticalPowerDbm
.innoTransTranscendModuleLaserEntry.15
Optical: Attn (dB)
Attenuation
.innoTransTranscendModuleLaserEntry.19
Chassis:
Temperature(C)
ModuleTemp
.innoTransTranscendModuleEntry.6
The Status:Opt is a special feature only available for Front Panel display, not available for SNMP or CLI interface.
7.3 PON EDFA Attributes
Front Panel
Display
CLI
SNMP OID
SNMP Trap ID
Status: Laser
Temperature (C)
LaserTemp
.innoTransTranscendModuleLaserEntry.3
Status: Bias (mA)
LaserBias
.innoTransTranscendModuleLaserEntry.13
Status: Optical
Input (dBm)
OPinPower
.innoTransTranscendModuleLaserEntry.11
Status: Optical
Output (dBm)
OPoutPower
.innoTransTranscendModuleLaserEntry.12
Alarm: Laser
Temperature
LaserTempAlarm
.iTTrancendNotification.10
Alarm: Optical Input OPinPowerAlarm
.iTTrancendNotification.15
Alarm: Optical
Output
OPoutPowerAlarm
.iTTrancendNotification.16
CHAPTER 7: