CHAPTER 5: SYSTEM TAB
5-18
MDU Solutions
®
– UCrypt
®
Monitoring Server - Operation Manual
Table 5 .10a: Power Section Confi guration (See Figure 5-42)
Field
Value
Description
Reboot Time/Delay
Integer
If specifi ed the reboot will occur at this time specifi ed in local server time as HH:MM
(24Hr) or +MM (minutes in the future). Default is
1 minute
in the future.
Reboot
Button
Reboots the Monitoring Server with a warm boot.
Shutdown
Button
Schedule a shutdown to occur in
1 minute .
Power off the system until it is manually
power cycled. This takes a unit out of service until fi eld personnel arrive for a power
recycle.
Cancel Shutdown
Button
Cancel pending shutdown or reboot if a shutdown was scheduled and it is decided to
not allow follow through. This button immediately cancels the pending action.
Power Cycle
Button
This feature is not implemented on this Server. The Monitoring Server is a Virtual
Machine.
Periodic Reboot
Dropdown Enables periodic reboot of machine at frequency chosen: Disabled, Daily or
Weekly(which will occur on Sunday).
Periodic Reboot Time Integer
The system may be confi gured to perform a reboot at the time specifi ed in the dialog
box. Time must be entered in 24 hour format using HH.MM notation.
Save Periodic Reboot Button
It is necessary to save the changes to the
Power
settings that were made. Failing to
save the settings will result in the changes being discarded when navigating away from
the System page.
5 .11 System Status
Many Linux and hardware status parameters are presented in the System Status section, see Figure 5-43. Your system values
will be different than those displayed here.
5 .12 Firmware
The fi rmware version installed is reported here, Figure 5-44. Firmware upgrades, when available, are obtained from ATX
Networks Technical Support group. Obtain the fi le and save it to your Management Computer before beginning the upgrade.
Figure 5-43: System Status Section
7
Figure 5-44: Firmware Version