CHAPTER 2: INSTALLATION

2-6 

VersAtive

®

Pro Mondo – Hardware Interface Manual

2.7.4  Re-Installing Inner Rails on Chassis    

The inner rails, 

Figure 2-3

, are factory installed, however, if they have been removed for any reason, follow this procedure to 

reinstall them.

1.  Confirm that the left and right inner rails have been correctly identified.
2.  Place the inner rail firmly against the side of the chassis, aligning the hooks on the side of the chassis with the holes 

in the inner rail.

3.  Slide the inner rail forward toward the front of the chassis until the rail clicks into the locked position, which secures 

the inner rail to the chassis.

4.  Secure the inner rail to the chassis with the screws provided.
5.  Repeat steps 1 through 4 above for the other inner rail.

Figure 2-3: Reinstalling lnner Rails

Figure 2-4: lnner Rails Installed

Summary of Contents for VersAtive Pro Mondo

Page 1: ...Hardware Interface Manual Patent Pending License free End of Sale as of March 31 2017 ...

Page 2: ...t The following symbols are in use NOTE This symbol usage will call the reader s attention to an important operation feature of the equipment which may be safety related or may cause a service outage FYI This symbol indicates that there is helpful related information available in this note or elsewhere in the guide DigiVu II DigiVu DigiVu UCrypt and VersAtive Pro are registered trademarks of ATX i...

Page 3: ...for IPMI 1 4 2 INSTALLATION 2 1 2 1 Chapter Contents 2 1 2 2 Preparation for Installation 2 1 2 3 Precautions 2 1 2 4 General Mechanical 2 2 2 5 Power Considerations 2 3 2 6 Gigabit Ethernet Ports 2 4 2 7 Installing the Chassis into a Rack 2 4 3 STARTUP 3 1 3 1 Chapter Contents 3 1 3 2 Management Computer 3 1 3 3 Connecting to Your Computer 3 1 3 4 Streaming Network Configuration 3 2 4 SAFETY 4 1 ...

Page 4: ... GENERAL GUIDE NOTES ii VersAtive Pro Mondo Hardware Interface Manual This page intentionally left blank ...

Page 5: ...ant to understand that the standard ATX Networks default IP address of 192 168 0 23 for the MGMT port is assigned to all nodes Before connecting each node management port MGMT ETH0 to the management switch the IP addresses must be re configured Refer to chapter STARTUP on page 3 1 for further guidance 1 3 Node Interface Panel The Mondo chassis includes four front control panels on the handles Figu...

Page 6: ...elated to its related node This section explains what each LED indicates when illuminated Alert This LED is illuminated when an alert condition occurs A solid red light indicates an overheat condition in the system A flashing red light which flashes in one second intervals indicates a fan failure A flashing red light which flashes in four second intervals indicates a power supply failure When noti...

Page 7: ...H4 12 ETH5 1 7 Unit Identifier Switches UID Two Unit Identifier UID Switch LED Indicators are available on each node The Front Panel UID Switch LED is located at the control panel adjacent each node see Figure 1 1 The Rear UID Switch is located next to the VGA Connector of each node see Figure 1 3 When the user presses a UID switch on the front panel or back panel both rear and front UID LED Indic...

Page 8: ... ftp supermicro com utility IPMIView The IPMI User Guides http www supermicro com manuals other Embedded_BMC_IPMI pdf http www supermicro com manuals other SMT_IPMI_Manual pdf IPMIView Software Manual http www supermicro com manuals other IPMIView20 pdf Command Line Interface tool ftp ftp supermicro com utility SMCIPMITool SMCIPMITool_User_Guide pdf NOTE Security measures should be taken if traffi...

Page 9: ... need to install the system into the rack Follow the steps in the order given to complete the installation process in a minimum amount of time 2 3 Precautions 2 3 1 Electrical Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the VersAtivePro Mondo chassis from damage Be aware of the locations of the power on off switch on the chassis as well as t...

Page 10: ... resting on them In single rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable and secured before extending a Mondo chassis from the rack You should extend only one Mondo chassis at a time extending two or more simultaneously may cause the rack to become unstable 2 4 General Mechanical ...

Page 11: ...n North America If shipped outside of North America the unit will be supplied with an IEC cord set appropriate for the locale to which it is shipped When installing the equipment it is the responsibility of the installer to determine that sufficient capacity is available in the electrical circuit feeding the unit to avoid overloading the supply circuit Each AC powered unit will require power to be...

Page 12: ...ection provides information on installing the Mondo chassis into a rack unit with the rails provided There are a variety of rack units on the market which may mean that the assembly procedure will differ slightly from the instructions provided You should also refer to the installation instructions that came with the rack unit you are using NOTE This rail will fit a rack between 26 5 and 36 4 deep ...

Page 13: ...ter rails Releasing Inner Rail from the Outer Rails Figure 2 2 1 Identify the left and right outer rail assemblies 2 Pull the inner rail out of the outer rail until it is fully extended as illustrated 3 Press the locking tab down to release the inner rail 4 Pull the inner rail all the way out 5 Repeat steps 1 3 for the second outer rail Figure 2 2 Release Inner Rail ...

Page 14: ...en correctly identified 2 Place the inner rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the rail clicks into the locked position which secures the inner rail to the chassis 4 Secure the inner rail to the chassis with the screws provided 5 Repeat steps 1 ...

Page 15: ...rail 3 Hang the hooks of the front of the outer rail onto the slots on the front of the rack If necessary use screws to secure the outer rails to the rack as illustrated above 4 Pull out the rear of the outer rail adjusting the length until it fits within the posts of the rack 5 Hang the hooks of the rear portion of the outer rail onto the slots on the rear of the rack If necessary use screws to s...

Page 16: ... of the outer rail and make sure that the ball bearing shuttle is at the front locking position of the middle rail 4 Align the chassis inner rails with the front of the middle rails 5 Slide the inner rails on the chassis into the middle rails keeping the pressure even on both sides until the locking tab of the inner rail clicks into the front of the middle rail locking the chassis into the fully e...

Page 17: ...treaming ports to a GbE capable switch or risk uncontrolled continuity errors as the 100 Base T network is flooded 3 1 Chapter Contents Management Computer Connecting to Your Computer Streaming Network Configuration 3 2 Management Computer It is required that the Management Computer meet these minimum requirements Wired Ethernet network port Web browser for Management GUI on 192 168 0 23 3 3 Conne...

Page 18: ...t eth1 Streaming or publishing exclusively for IP based streaming content eth2 Streaming or publishing exclusively for IP based streaming content eth3 Streaming or publishing exclusively for IP based streaming content eth4 Streaming or publishing exclusively for IP based streaming content eth5 Streaming or publishing exclusively for IP based streaming content IPMI DHCP enabled hardware level inter...

Page 19: ...d in the operating instructions or as marked on the device NOTE a For 115 VAC operation use the power cord supplied for operation from a 115 VAC source b For 230 VAC operation use the power cord supplied for operation from a 230 VAC source POWER CORD PROTECTION Power supply cords should be routed so that they are not likely to be pinched by items placed upon or against them paying particular atten...

Page 20: ...CHAPTER 4 SAFETY 4 2 VersAtive Pro Mondo Hardware Interface Manual This page intentionally left blank ...

Page 21: ...SUPPORT Tel 905 428 6068 Toll Free 800 565 7488 USA Canada only Press 3 for Technical Support Then press 1 for Digital Video Products DVIS DigiVu UCrypt VersAtivePro DigiStream Email digitalvideosupport atxnetworks com CUSTOMER SERVICE ATX Networks 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 905 428 6068 Toll Free 800 565 7488 USA Canada only Press 1 for Customer Service Fax 905 427 1964 T...

Page 22: ...17 ANW1110 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 1 905 428 6068 Toll Free 1 800 565 7488 Fax 1 905 427 1964 Toll Free Fax 1 866 427 1964 www atxnetworks com support atxnetworks com End of Sale as of March 31 2017 ...

Reviews: