background image

TH146-P-DE 

      400-280-004-C                    11/29/06                    1/9

TH146-P-DE

Installation Guide

Programmable Heat Pump Controller

-

The TH146-P-DE programmable controller can be used to control a
heat pump system. The following devices can be connected to the
controller:

heat pump 

auxiliary heating (furnace)

air recirculation fan

humidifier

dual-register meter (dual energy)

remote control device (for the unoccupied mode)

• CT280-HP-2H1C control module
• TH146-P console with two wall anchors and mounting screws
• AC144-03 outdoor temperature sensor (3 m or 10 ft) with

mounting clip (see section 2.7)

• RC845 relay (see section 2.5)
• AC146-410 plenum temperature sensor (see section 2.8)
• CT241 telephone controller (see section 2.10)

Install the control module on the furnace’s electrical panel, away
from the heat source.

Install the console in the area where you wish to measure the tem-
perature and humidity. Avoid locations where there are air drafts
(e.g., top of staircase or air outlet) or stagnant air (behind a door).
Do not install the console on a wall hiding air ducts nor expose it to
direct sunlight.

NOTE

: If this controller replaces an existing thermostat, the wires

that were connected to the thermostat can be used to connect the
console. The maximum wire length is 30 m (100 feet).

1)

Choose a location about 5 ft. (1.5 m) above the floor on an 
inside wall.

2)

Loosen the captive screw under the console.

3)

Detach the console from its base by pulling the bottom section.

4)

Secure the base using the wall anchors and screws.

5)

Connect the console to controller terminals TH and TH (no 
polarity).

Connect the heat pump to the controller as follows:

• Controller terminals R and C to heat pump terminals R and C

(see section 2.4)

• Controller terminal Y to heat pump terminal Y
• Controller terminal O/B to heat pump terminal O
• Controller terminal WW to heat pump terminal WW

TH146-P User Console

CT280-HP-2H1C Control Module

AC144-03 Outdoor
Temperature Sensor

1. Introduction

1.1

Applications

1.2

Supplied Parts

1.3

Accessories

2. Installation

2.1

Control Module (CT280-HP-2H1C)

2.2

User Console (TH146-P)

2.3

Heat Pump

Summary of Contents for TH146-P-DE

Page 1: ...or air outlet or stagnant air behind a door Do not install the console on a wall hiding air ducts nor expose it to direct sunlight NOTE If this controller replaces an existing thermostat the wires tha...

Page 2: ...oller terminals PS and CS no polarity For more information refer to the instructions provided with the sen sor NOTE The maximum wire length is 30 m 100 feet The dual energy input can be connected to t...

Page 3: ...utdoor temperature is above the balance point high bP H the auxiliary heat is disabled see page 4 item 6 and only the heat pump can be used NOTE Balance points will not work if the AC144 03 outdoor te...

Page 4: ...point high 5 C to 30 C 23 F to 86 F 5 C 41 F Set the bP H value see section 4 2 7 Defrost point 10 C to 15 C 14 F to 59 F 10 C 50 F During defrost auxiliary heating is activated when the outside temp...

Page 5: ...ion Diagram New Installation TH146 P AC144 03 AC146 410 CT241 Humidifier Heat Pump Compressor Fault CT280 HP 2H1C Fan Auxiliary Heat Defrost Valve Dual Energy 16 22 AWG 16 22 AWG 16 22 AWG 16 22 AWG 1...

Page 6: ...Transformer Dual Energy AC144 03 AC146 410 CT241 RC845 Humidifier Auxiliary Heating System Heat Pump Compressor Defrost Fault Furnace Fan Limit CT280 HP 2H1C Yellow Red Green Reversing Valve 16 22 AWG...

Page 7: ...n Program clear Humidity setting Return Temperature adjustment mode selection Fan operating mode selection System operating mode selection Up Down buttons Indicator LEDs FAULT System fault EH Emergenc...

Page 8: ...days are selected they will all now have the same settings for period 2 To set the start time of a period first press Pgm until the period number P1 to P4 is displayed and the time display flashes The...

Page 9: ...rchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option If the product is defective...

Reviews: