1) Press Clk. The hour display flashes.
2) Set the hour using

.

3) Press Clk. The minute display flashes.
4) Set the minutes using

.

5) Press Clk. The day display flashes.
6) Set the day using

.

7) Press

 to return to the normal display.

1) Press Clk for 3 seconds to display the year.
2) Set the year using

.

3) Press Clk to display the month.
4) Set the month using

.

5) Press Clk to display the date.
6) Set the date using

.

7) Press

 to return to the normal display.

Press the Fan button to select the fan operating mode.

• In automatic mode, the fan runs only when heating or cooling

is activated. 

NOTE: For gas-operated HVAC systems, there 

might be a delay before the fan starts or stops when heating 

is activated or deactivated.

• In continuous mode, the fan runs continuously and the

symbol is displayed. 

NOTE: if Smart Fan is enabled, when 

the controller is in periods 2 and 4 of automatic mode and in 

unoccupied mode, the fan will run only when heating or 
cooling is activated. The fan will run continuously the rest of 

the time.

Press Mode to place the system in one of the following modes: 

You can place the controller in the unoccupied mode using a remote 
control device such as Aube’s CT241 telephone controller. In this 
mode, the temperature is lowered in heating mode or raised in 
cooling mode. The amount of temperature setback is set using the 
configuration menu (see installation guide). The message UNOC 
appears during the unoccupied mode.

NOTE: Automatic changeover is disabled during the unoccupied 

mode.

Temporary Bypass

In the unoccupied mode, only the 

 buttons work. When you 

adjust the temperature during this mode, the new temperature will 
be used for the next 2 hours, after which the controller will return to 
the previous setpoint. The message UNOC flashes during the 
bypass.

Time and day setting

Programming

Program day selection

Program clear

Humidity setting

Return

Temperature 
adjustment 
mode selection

Fan operating 
mode selection

System operating 
mode selection

Up/Down buttons

Indicator LEDs

FAULT

: System fault

EH

: Emergency heat mode

DE

: Dual energy

Day

Clock

Indoor temperature

Outdoor temperature

Indoor humidity

Indicator LEDs

Backlight

The screen is lit for 12 seconds
when any button is pressed.
However, the screen remains lit
while you are configuring the
controller.

1. General Settings

1.1

 Clock and Day Setting

1.2

Date Setting

2. Operating Modes

2.1

Fan Operating Modes

2.2

System Operating Modes

HEAT

The system is in heating mode.

COOL

The system is in cooling mode.

AUTO

The system is in automatic changeover mode. (The 
system switches between heating mode and cooling 
mode to maintain the desired temperature.)

OFF

The system is off.

EHEAT

The system is in emergency heat mode. Only auxiliary 
heating is used when there is a call for heat. (This 
mode applies only when the controller is connected to 
a heat pump equipped with auxiliary heating).

2.3

Unoccupied Mode / Temperature Setback

This is a legacy product document 
supported by Resideo. It is no  
longer manufactured 

Summary of Contents for TH146-P-U

Page 1: ...tion guide The message UNOC appears during the unoccupied mode NOTE Automatic changeover is disabled during the unoccupied mode Temporary Bypass In the unoccupied mode only the buttons work When you a...

Page 2: ...4 is displayed and the time display flashes Then press the buttons The time changes in increments of 15 minutes NOTE To skip a period display the period and press Clr For example in the pre programmed...

Page 3: ...duration the controller will revert to the mode in which it was previously humidity control mode or off at the end of the air exchange mode To deactivate the air exchange mode 1 Press the Hum button...

Page 4: ...duct within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH O...

Page 5: ...Dans ce mode la temp rature de consigne est abaiss e en mode chauffage ou augment e en mode climatisation L cart de temp rature est regl partir du menu de configuration voir le guide d installation Le...

Page 6: ...e P1 P4 soit affich et que l heure clignote Appuyer ensuite sur les boutons L heure se r gle 15 minutes pr s NOTA Pour sauter une p riode afficher la p riode et appuyer sur le bouton Clr Par exemple d...

Page 7: ...humidit ou arr t la fin du mode d change d air Pour quitter le mode d change d air 1 Appuyer sur le bouton Hum jusqu ce que l cran affiche l une des mentions suivantes AUTO l changeur d air est en mo...

Page 8: ...ELL N EST EN AUCUN CAS RESPONSABLE DES PERTES OU DOMMAGES Y COMPRIS LES DOMMAGES INDIRECTS OU ACCESSOIRES D COULANT DIRECTEMENT OU INDIRECTEMENT D UNE VIOLATION QUELCONQUE D UNE GARANTIE EXPRESSE OU T...

Reviews: