AT

. Auto-tune function. Set AT to 1 then exit the menu. The display will 

start to flash alternately between AT and the current temperature, which 
indicates auto-tuning is in progress. When the display stops flashing, the 
auto-tuning is finished. Now, the newly calculated PID parameters are set 
and are used for the system. The new parameters will store in the 
memory even the power is off  

      

C-F.

 Temperature display unit. You can set the unit either to Celsius or 

Fahrenheit. 

      

oFS.

 Input Offset. oFS is used to compensate the error produced by the 

sensor or input signal itself. For example, if the unit displays 37 degree 
when the actual temperature is 32, set parameter oFS = - 5 will make the 
controller display 32 degree. The displayed process temperature = actual 
measured tempe oFS.   

6. Recommended Parameter for Sous Vide Cooking 

The default setting: P=18, I=650, d=40, and t=20 is optimized for Sous Vide 
cooking with rice cooker or steam table. 

7. Connecting the Sensor to the Controller 

The connector of sensor contains a slot for fitting pin connection. It also has a 
spring lock to prevent disconnections from accidental pulling on the cable. To 
install the to the unit, please align the slot of the female connector on the 
sensor to the red mark of the male connector on the unit, then hold the tail and 
push the female connector forward. To remove the connector, please pull the 
spring-loaded collar of the female connector. Please see the Figure 3 and 
Figure 4 below for details. 
 

 

 

Figure 3. Install the Sensor. 

 

 

 

Figure 4. Remove the Sensor. 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Auber Instruments Inc. 

5755 North Point Parkway, Suite 99, 

Alpharetta, GA 30022 

www.auberins.com 

E-mail: info@auberins.com Tel: 770-569-8420 

 

Copyright 2007-2017, Auber Instruments All Rights Reserved. 

No part of this manual shall be copied, reproduced, or transmitted in any way without the 

prior, written consent of Auber Instruments. Auber Instruments retains the exclusive 

rights to all information included in this document. 

 