background image

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         

WWW.AUBERINS.COM  

 

 

         2018.02                                                                     

   

                                                       P2/3 

 

parameter. See figure 3 on next page for the procedure. For the definition of 
each programming value, see following section. 

 

trnG
S

tdir
dn

0000

tot

Accumulated Value
Total Time

trnG

s

0000

0000

Process Time
Set Time

SET

tAdj

on

TDIR

dn

SET

Tl.a

1

disp

Tot

Tl.b

1

SET

SET

SET

3 seconds

SET

SET

5 seconds

0000

cups

Accumulated Value
Total cups

 

Figure 3. Flow chart of programming 

 

5.1 How to Set the Timer and Dose Time T1/T2. 
When timer is not running,

 in single/double dose display mode,  

a) P

ress “SET” key to shift between single dose time T1 and double dose time 

T2. When parame

ter “tAdJ” is programmed to “ON” (see definition of “

tAdJ

” in 

next section), simply press up/ down key will increase/decrease the set value 
of each delay time. (Hold up/down key will increase the changing speed 
exponentially). 

b) Hold “SET”

 key for 3s, the display will change to total running time/cups 

display mode. For how to program two different display modes, please see the 
d

efinition of “

dISP

” in next section.     

 

c) H

old “SET” key for 5s, th

e display will enter parameter programming menu. 

      

5.2 Definition of Programming Values.

 

trnG: timer range. 

S: 0.01 s ~ 99.99 s.  
M:S: 1 s ~ 99 m 59 s. 
 

tdir: timing direction.  

up: counting up. 
dn: counting down. 
*Note: the timing direction can only be changed in the single and double dose 
timer display. The manual control always counts up so that user can use its 
value to fine tune the single and double dose setting. 
 

tAdJ: time adjust. 

On: When timer is not running, adjust timer directly by pressing up/down key 
from the front panel. 
Off: Values for timer T1/T2 are locked. 
 

dISP: display mode. 

Tot: total time (unit: second).  
CUPS: number of cups. 
*Note 1: in Tot mode: total time will only display integer part; when manual key 
is pressed and held, the running time is counted into total time until the manual 
switch is released. 
*Note 2: in CUPS mode: number of cups will not be counted into total number 
when manual key is pressed. 
*Note 3: press down key for 4 seconds will reset the display to zero in both 
modes. 
 

tLA: constant A.    
tLb: constant b. 

These two constants are used for converting the total time display to other 
units, such as weight in grams.  

dISP = T x A/b,  

where T = T1 or T2. For example, if grind 1 gram of coffee takes 2 seconds, set 
A = 1, b = 2, this will convert the total display unit from second to gram.  
 

6. Wiring Examples 
6.1 Wire JSL-

72 timer as Auber’s

 J72BX -- Coffee Grinder Timer Controller.  

To make a control box similar to Auber’s J72BX for grinder, please refer to the 

wiring diagram in Figure 4. PLEASE NOTE: this setup is only suitable for 
grinders with motors that consume less than 300 W power.  
  

6

7

8

9

10

1

2

3

4

5

N

L

G

G

To Enclosure Ground

Output Socket

Manual

T2

T1

120VAC

N

G

Input Power 

Socket

L

L

N

 

Figure 4. Wiring diagram of J72BX. 

 
 

6.2 Wire JSL-

72 timer as Auber’s

 J72MA -- Timer Controller for Mazzer 

Automatic Grinder. 

To make a control box similar to Auber’s J72MA for 

Mazzer Automatic Grinder, 

please refer to the wiring diagram in Figure 5.  
 

6

7

8

9

10

1

2

3

4

5

Manual

T2

T1

120VAC

L

N

G

To Enclosure Ground

Input Power 

Socket

Output Socket to 

the Coil of Grinder

Contactor.

N

L

 

Figure 5. Wiring diagram of J72MA. 

 
 

6.3 Wire JSL-72 timer

’s output

 in parallel to a grinder

’s power switch

.  

Reviews: