SYL-2813A Dual-Input Automotive Multimeter 

Version 1.6 (Mar, 2019) 

 

A. Specifications   
 

Table 1. Specifications of SYL-2813A Automotive Multimeter. 

Power Supply

 

DC 12 -30 V (Isolated)

 

Power Consumption

 

< 2 Watt

 

Relay Contact Rating

 

3 A at 220 VAC

 

Input Type

 

Thermocouple

: K, E, S, R, J, T, B, WRe3/25.  

Resistance

: Pt100, Cu50, (375R)*   

Voltage

: 75 mV, 30 mV, 0 - 5V, 1 - 5V, 10 V  

Amperage

: (0 - 10 mA, 0 - 20 mA, 4 - 20 mA)*

 

Input Channels

 

Channel 1, Channel 2

 

Display Range

 

-1999 ~ 9999

 

Accuracy

 

± 0.2% of full input range or ± 1 unit

 

LED Display

 

0.48’’ red/green color

 

Outside Dimension

 

48 x 48 x 75 mm (1/16 DIN)

 

Mounting Cutout

 

45 x 45 mm

 

Working Condition

 

-20 ~ 50

˚

C, 85% RH

 

 

Note

: * input types that are in parenthesis are only available to channel 1, these input 

types are not available to channel 2.  

 

 

B. Front Panel 
 


 

Figure 1. Front panel of SYL-2813. 

 

 Alarm1 and relay J1 indicator (red LED) 

 Alarm2 and relay J2 indicator (red LED) 

 Maximum value indicator of Channel1 (red LED) 

 Maximum value indicator of Channel2 (red LED)    

 SET key  

 SHIFT key 

 DOWN key  

 UP key     

 Display1 window (top display) 

 Display2 window (bottom display)

 

 

1. AL1 (or AL2) on indicates alarm is on and J1 (or J2) relay is pulled in 

(closed). 

2. PK1 (or PK2) is on when display windows shows the maximum value MA1 

of Channel 1 (or the MA2 of Channel 2) and the time MAt1 (or MAt2) when the 
peak value was caught.  

 

3. SET key. In Normal Operating Mode, press SET once, enter the code for a 

setting mode. Press SET again to enter the setting mode. In Parameter Setting 
Mode, press it to select a parameter or to save the value.    
4. SHIFT key “>”. In the Parameter Setting Mode, press this key to select the 
digit to be changed. In the Normal Operating Mode, press this key to toggle the 
displayed variables between Process Values (PV1 and PV2), Maximum Value 
of Channel 1 (MA1 and MAt1), and Maximum Value of Channel 2 (MA2 and 
MAt2). See the diagram below. Please note that time is expressed in seconds 
when it is less than 9999 seconds. Time longer than 9999 seconds will be 
displayed as Hours. Minutes (hh.mm). 
5. DOWN key “V”. In the Parameter Setting Mode, press it to scroll the 
parameter list in a reversed order or decrease the parameter value. In the Peak 
Value Checking Mode, press it for 2 seconds to reset the peak values stored in 
the memory. In the Normal Operating Mode, press this key to toggle the 
display the current readout and value difference if the feature is enabled.  
6. UP key “

Λ

”. In the Parameter Setting Mode, press it to scroll the parameter 

list or to increase the parameter value. In the Normal Operating Mode, press 
this key to toggle the display brightness between bright and dim. Each time the 
key is pressed the display brightness will be changed. 
 

PV2

PV1

MAt1

MA1

MAt2

MA2

Process Values

(PK1 and PK2 are off)

Peak Value of 

Channel 1 

(PK1 on)

Peak Value 

of Channel 2 

(PK2 on)

“>” Key

“>” Key

“>” Key

 

Figure 2. Diagram of how to check Peak Values. 

 
 

C. Terminal Assignments 

6

7

8

9

10

14

13

12

11

1

2

3

4

5

SYL-2813

J1 output 

(NO)

J2 output 

(NO)

DC 12V

Gnd

TC1

mA1
mV1

TC2

mV2

RTD1

RTD2

P2 (V2)

P1 (V1)

Light

Int.

5V out

COM

(J1/J2)

+

 

 

Figure 3. Terminal assignments of SYL-2813. 

 

Instruction Manual

 

Summary of Contents for SYL-2813A

Page 1: ... to enter the setting mode In Parameter Setting Mode press it to select a parameter or to save the value 4 SHIFT key In the Parameter Setting Mode press this key to select the digit to be changed In the Normal Operating Mode press this key to toggle the displayed variables between Process Values PV1 and PV2 Maximum Value of Channel 1 MA1 and MAt1 and Maximum Value of Channel 2 MA2 and MAt2 See the...

Page 2: ...T1 and T3 connect white wire to T5 for a two wire RTD connect the red wire to T3 and connect the white wire to T5 and short T3 and T1 See Figure 4 b 5 Wiring of Pressure Sensors In Channel 1 connect the power source wire of the sensor to T9 the signal wire of the sensor to T13 and the ground wire of the sensor to T1 In Channel 2 connect the power source wire of the sensor to T9 the signal wire of ...

Page 3: ... SET key once the upper window will display pass and the lower window will display 0000 Change the number to 0089 in the lower window and press SET again to enter the Parameter Setting Mode Two parameters from the parameter list will be displayed The upper window will flash the first parameter the lower window will steadily display the next parameter on the list see table 3 Use UP or DOWN key to s...

Page 4: ...36 D 3 c Check the Peak Value To check the Peak Value during operation mode use the SHIFT key Press once the PK1 indicator will be on MA1 and MAt1 will be displayed in the upper and lower window respectively Press key again the PK2 indicator will be on MA2 and MAt2 will be displayed in the upper and lower window respectively press again to exit this mode and return to the Normal Operating Mode D 3...

Page 5: ... Oil Temperature To measure temperatures with one thermocouple sensor and one RTD sensor you can wire the sensors to SYL 2813 gauge as the diagram in Figure 9 In this diagram the thermocouple is connected to the Channel 1 and the RTD sensor is connected to the Channel 2 You will need to change the input types and other parameters for Channel 1 and 2 accordingly E 3 Read Temperature Difference Betw...

Reviews: