V4.5
©2015-2019 AUBO.All rights reserved.
77
Electrical parameters at the VI end
Parameter term
Minimum value
Maximum value
Units
Input voltage
0
+10
V
Input resistance
100K
Ω
VI sampling resolution
12
BITS
VI sampling accuracy
10
BITS
VO end electrical parameters
Parameter term
minimum value
Maximum value
Single VO terminal input voltage
0V
+10 V
Single CO terminal input current
0mA
20 mA
Example
Analog voltage output wiring method
For the analog voltage output, refer to the wiring method shown in the figure below.
Figure 8-25 Analog output drive differential device
Analog voltage input wiring method
External sensor wiring: