V4.5
©2015-2019 AUBO.All rights reserved.
78
Figure 8-26 connect to sensor
Analog current output wiring method5
The analog current output can be wired as shown in the figure below.
Figure 8-27Analog current output connect to current source
Clear alarm signal interface
F6 on the back panel of the control box is the clear alarm signal interface. This signal is active low.
Remote switch control I/O interface
The remote power on/off control I/O interface is located on the back panel interface board of the control
box, as shown in the figure below.
Figure 8-28 Remote I/O interface control I/O interface
Using the remote power on/off control I/O interface allows you to control the teach pendant and robot
body to be turned on or off without the use of a teach pendant.