Note: This
configuration of two
9871 Drivers could
support four
wallplates.
9871
Driver
Note: IR remote control
system and receivers are
not included.
A
9871
Driver
B
A
B
In Case of Difficulty
If any problems arise that are not covered in this
manual, call Audio Authority Technical Support at
800-322-8346, or outside the US and Canada, call
859-233-4599.
IR Remote
Control
System
IR Receiver
9878
Wallplate
AV Equipment
IR
Remote
Cat 5, Cat 5e,
or Cat 6 Cable
AV Equipment
18-volt power supply PN 571-014
18-volt power supply PN 571-014
Cable Length
Compensation = 4
Cable Length
Compensation = 3
Cat 5 Cable Length = 370 ft.
Cat 5 Cable Length = 250 ft.
RCA Cable Length = 220 ft.
A
9871
Driver
B
9878
Wallplate
9878
Wallplate
AV Source Component
coaxial cable by increasing the cable compensation setting by one click for each 200 feet of coaxial cable length
(see diagram below). For example, if the coaxial cable length from main system to Driver is 220 feet (1 click)
and the Cat 5 cable length to a certain wallplate is 250 feet (2 clicks), the correct Cable Length Compensation
for that wallplate is 1 + 2 = 3 clicks. Conditions vary, so it is best to verify settings using the video display that
will be installed in each location.
A pass-through F-connector is provided in case antenna connection is desired. (A separate coaxial cable must
be pulled; antenna signals are not carried on the Cat 5 cable).
Connecting to an IR network
The DuoDrive does not have an IR remote control system; it provides a discrete three-strand Cat 5 pathway
for a third party system. Connect an IR remote control system input to the Driver IR output stereo 3.5mm jack
(see example diagram below). Connect an IR receiver to each wallplate/receiver and position them appropriately
in the rooms. Do not connect any equipment to the vacant white RCA jacks marked “IR”.