ATIR-T88
◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆
◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆
142313570
FH-2871a
1423-13570
MANUAL T88 T85
ATIR-T88̲T85
ATIR-T85
機種名
版下No.
P.CODE
品 名
Accessories
Modulation method
Carrier frequency
Technical Data
※
【Example】
Operation
●
●
http://www.audio-technica.co.jp
HI
LO
ECO
approx.10hrs.
Audio-Technica Oversea office
Audio-Technica U.S.,Inc
1221,Commerce Drive,Stow,Ohio 44224 USA
+1(330)686-2600
Audio-Technica Limited(UK)
Technica House
Royal London Industrial Estate,Beeston,Leeds,LS11
England
+44(0)113 227 1441
Audio-Technica (Greater China)Limited
Unit K,9/F1,Kaiser Eatate (Phase2)
51Man Yue Street,Hunghom,Kowloon Hong Kong
+852-2356-9268
Audio-Technica (S.E.A)Pte Ltd
1 Ubi View #01-14 Focus One Singapore 408555
+65-6749-5686
Audio-Technica Taiwan Co.,Ltd Taipei Branch
2F,No.85,Sec. 1,Da-an Rd., Taipei City 10688,Taiwan
+886-2-8772-8608
Audio-Technica Corporation
2206 Naruse Machida,Tokyo Japan
Tel.(042)739-9111
: Frequency modulation
approx.
approx.
6hrs.
3hrs.
:
:
:
●
:
HI
LO
ECO
approx.10hrs.
:
:PLL synthesizer
:
Ch. B 2.66
MHz
Ch. C 3.18
MHz
approx.
approx.
6hrs.
3hrs.
:
120×60×23
mm
(excluding the belt clip)
:
approx. 66g(body only)
Dimensions
88.5×28×23
mm
:
:
:
:
Weight
: approx. 48g(including the tie clip)
Channel labels,small screwdrivers
:
Accessories
●
Setting
1
1
3
2
A
B
A+B
B+C
⇒
⇒
⇒
⇒
Ch. A is available.
Both Ch. A and Ch. B are available.
Priority setting
Channels to use
Instruction Manual
Common Features
These microphones are designed for use in presentation
applications with the ATCS-60 infrared conference system.
●
●
●
●
Infrared Handheld Microphone
Features
Infrared Lavaliere Microphone
Features
●
●
●
●
●
●
●
CAUTION on battery handling
WARNING
CAUTION
WARNING
DANGER
Safety Precautions
CAUTION on installation
・Lighting equipment
・Projector (liquid-crystal, DLP), OHP, incandescent bulbs
・Mercury lamp, halogen lamp and inverter fluorescent lamp, black light
・ Plasma displays
・Infrared devices, such as remote control, infrared microphone and infrared LAN
・ Cooking devices
・Digital equipment, such as digital power amplifiers and cables including
speaker output lines
Infrared Handheld Microphone: ATIR-T88
Type
Back electret condenser
Directivity
Unidirectional
Infrared wavelength
870 ±30 nm
Oscillation system
PLL synthesizer
Frequency response
100 to 15,000 Hz
:
:
:
:
:
:
Battery
: Two AA alkaline batteries
Ch. A 2.38 MHz
Ch. B 2.66 MHz
Ch. C 3.18 MHz
Continuous operation time
Dimensions
(head diameter x overall length)
59 mm dia. x 262 mm
Weight
approx. 240 g (body only)
Channel labels, small screwdrivers
Infrared lavaliere Microphone: ATIR-T85
Type
: Electret condenser
Directivity
Unidirectional
Infrared wavelength
870±30 nm
:
Oscillation system
Frequency response :100 to 15,000 Hz
Modulation method
Frequency modulation
Carrier frequency
: Ch. A 2.38MHz
Battery
: Two AA alkaline batteries
Continuous operation time
Transmitter
Dimensions
Weight
Micrphone
3.5 mm dia., 1.0 m long
Cord
Plug
L-shaped min subminiature plug
Troubleshooting
The microphone does not turn on.
Are the batteries installed?
Is the battery polarity correct?
No sound.
How to set up the ATCS-C60
8AG
※
Channels to use
A
B
A
+
B
B
+
C
A
+
B
+
C
TEST
switch
3
4
5
6
7
Priority setting First In First Out
1 or more(6 or more)
2 or more(7 or more)
3 or more(8 or more)
(Last In First Out)
2 or more(7 or more)
3 or more(8 or more)
1. Use the TEST switch on the ATCS-C60 front panel to
specify the number of handheld/lavaliere microphones
and the channels to use.
2. Use the PRIORITY switch on the ATCS-C60 to select
the priority number corresponding to the used channel.
To enable the settings, press the SET button or restart
the ATCS-C60.
When the priority setting on the ATCS-C60 and the
used channels do not match, the handheld/lavaliere
microphones are not available.
When the ATCS-C60MAG is used, specify the
number of prior microphones in the Priority field on
the mode setting screen corresponding to the used
channel.
The PRIORITY switch setting on the ATCS-C60 will
be disabled when the ATCS-C60MAG runs.
When the priority setting on the ATCS-C60MAG and
the used channels do not match, the handheld/
lavaliere microphones are not available.
The set priority number is too low
to use the channel.
The set priority number is too low
to use the channels.
For product warranty and service, contact your local sales representative or
business office listed below.
Infrared Conference System
Presenter Microphones
This system uses infrared technology for transmission,not
radio waves,thereby eliminating signal transmission outside
the room of use.
Up to three presenter microphones can be used together
with the ATCS-M60 conference unit at the same time.
For battery conservation,the power switch can be set to
any of three output levels (ECO,LO and HI)as determined
by room size.
(Continuous operation time in ECO mode is approximately
10 hours.)
The IR transmitting sections are located in the
upper and lower sections of the grip.
The condenser microphone element features
high quality sound and sensitivity.
The lavaliere microphone is designed for use
by conference chairpersons and lecturers.
The lightweight, compact body is useful for
mobile applications.
The tie clip allows easy attachment and
direction angle adjustment.
The transmitter can be clipped to a belt.
The condenser microphone element features
high quality sound and sensitivity.
Thank you for purchasing our products. Be sure to read this manual before use.
Store it with the warranty form in a readily accessible place.
● The IR receiving unit is highly sensitive and direct sunlight may generate
noise. Use curtains or shades for the windows in this case.
● Do not put the product in an environment with vibration or shocks or on
unstable tables and tilted surfaces. Drops or falls may cause injury.
● Do not install the IR receiving unit near lighting devices or places exposed
to spotlights.
● Infrared operating distance may vary depending on the color and material
of the ceiling and walls.
● Noise may be generated regardless of the operating distance. In this case,
install the IR receiving unit and the receiver in the proper position.
● When installing the IR receiving unit in the ceiling, keep it at least 2 to 3
meters away from windows or walls.
● When installing the IR receiving unit on the wall, keep it at least 2 to 3
meters away from the ceiling.
● Install the IR receiving unit at least 50 cm away from fluorescent lamps.
● Large electrical equipment placed over the audio line and IR receiving unit
cables may cause noise.
● Occasionally, this system cannot be used at the same time as other
infrared devices such as PDPs and simultaneous interpretation systems.
● In addition, the IR receiving unit or the receiver installed near the
infrared-emitting sources listed below may cause system malfunction or
noise.
Ensure that the microphones are kept away from infrared or noise sources.
● Do not disassemble the product. Failure to heed this warning may result in
fire, electric shock, or equipment malfunction.
● Do not expose the product to high humidity or liquids. Failure to heed this
warning may result in fire, electric shock, or equipment malfunction.
● Do not use the product near a cooking table where it may be exposed to
oil, smoke, and steam.
● Do not put the product in an environment with vibration or shocks. Drops
or falls may cause injury.
● Do not leave the plastic packing bags within reach of children or near fire.
● Do not expose the product to direct sunlight, heating appliances, or a
dusty environment.
DANGER
● If a battery leaks and the liquid contacts the eyes, immediately wash
thoroughly with clean water without rubbing and seek medical treatment.
● Do not peel off the vinyl cover from the batteries.
Failure to heed this warning may result in a short circuit and may cause
the battery to burst or leak, resulting in fire or personal injury.
● Do not incinerate or heat the batteries. Failure to heed this warning may
result in a fire.
● Do not short-circuit positive and negative terminals with any metal or wire.
Failure to heed this warning may result in a fire or personal injury.
In addition, do not carry or store batteries with other metal products.
● If the battery leaks or becomes discolored or distorted, immediately remove
the batteries. Do not use them anymore.
● Store batteries out of the reach of children. If a person swallows a battery,
seek medical treatment.
● Do not use or leave batteries near fire, exposed to direct sunlight, or in a
high temperature environment such as inside a sun-heated car.
● This product uses two AA dry batteries, which you must purchase separately.
Use the same kind of batteries.
● Do not disassemble or modify the batteries.
● If a battery leaks, thoroughly wipe out the liquid from the battery case
before replacing with new batteries.
● If a battery leaks and the liquid contacts your skin or clothing, immediately
flush with clean water.
● Remove the batteries if you will not use the product for a long time. After a
long continuous use of batteries, replace them with new ones.
Is the volume control of the connected master
unit fully turned down?
Is the ATIR-T85 microphone plug securely
connected to the transmitter input terminal?
Are the TEST and PRIORITY switch selection
for the ATCS-C60 or the ATCS-C60MAG
settings correct?
NOTE:
※
For operating instructions on the conference system
(ATCS-60), refer to the manual supplied with the system.