• Tailored for smooth, natural vocal reproduction

• Cardioid polar pattern reduces pickup of sounds from the sides 

and rear, improving isolation of desired sound source 

• Durable performance for professional applications

• Hi-ENERGY

®

neodymium magnet for improved output and 

transient response  

• Excellent off-axis rejection for minimum feedback 

• Superior anti-shock engineering for low handling noise 

• Multi-stage grille design offers excellent protection against plosives 

and sibilance without compromising high-frequency clarity 

• Quiet-Flex

stand clamp provides silent, flexible microphone 

positioning 

• Corrosion-resistant contacts from gold-plated XLRM-type 

connector 

• Rugged, all-metal design and construction for years of trouble-free 

use

Output from the microphone's XLRM-type connector is low 
impedance (Lo-Z) balanced. The signal appears across Pins 2 and
3; Pin 1 is ground (shield). Output phase is “Pin 2 hot” – positive
acoustic pressure produces positive voltage at Pin 2.

To avoid phase cancellation and poor sound, all mic cables must be
wired consistently: Pin 1-to-Pin 1, etc. For a high-impedance (Hi-Z)
mic input, connect a Lo-Z balanced cable to a Hi-Z matching 
transformer (A-T CP8201 or equal) at the equipment input.

When using the ATM410 in settings with a stage monitor speaker,
the speaker should be located 180° off axis (at the rear of the 
microphone). This placement, in conjunction with the microphone's
uniform cardioid pickup pattern, will virtually eliminate the possibility
of undesired audio feedback.

Take care to keep foreign particles from entering the windscreen. An
accumulation of iron or steel filings on the diaphragm, and/or foreign
mater ial in the windscreen's mesh surface, can degrade 
performance.

Audio-Technica U.S., Inc., 

1221 Commerce Drive, Stow, Ohio 44224

Audio-Technica Limited,

Old Lane, Leeds LS11 8AG England

www.audio-technica.com

P51802     ©2006  Audio-Technica U.S., Inc.    Printed in China

ATM410

ATM410 SPECIFICATIONS

ELEMENT

Dynamic

POLAR PATTERN

Cardioid 

FREQUENCY RESPONSE

90-16,000 Hz

OPEN CIRCUIT SENSITIVITY

–55 dB (1.7 mV) re 1V at 1 Pa*

IMPEDANCE

300 ohms

WEIGHT

233 g (8.2 oz)

DIMENSIONS

170.0 mm (6.69") long, 
53.5 mm (2.11") diameter

OUTPUT CONNECTOR

Integral 3-pin XLRM-type

ACCESSORIES FURNISHED

AT8470 Quiet-Flex

stand clamp 

for 

5

/

8

"-27 threaded stands;

5

/

8

"-27 to 

3

/

8

"-16 threaded adapter;

soft protective pouch

†In the interest of standards development, A.T.U.S. offers full details on its test 

methods to other industry professionals on request.

*1 Pascal = 10 dynes/cm

2

= 10 microbars = 94 dB SPL

Specifications are subject to change without notice.

CARDIOID DYNAMIC 

VOCAL MICROPHONE

8 kHz

Polar Pattern

SCALE IS 5 DECIBELS PER DIVISION

LEGEND

200 Hz

1 kHz
5 kHz

Frequency in Hertz

LEGEND

12" or more on axis

Frequency Response

Response in dB

Reviews: