background image

Installation & Maintenance Manual 

 

11. Installing and Configuring the SBA 

Version 6.8 

139 

Microsoft Lync Server 

11.19.2  Starting and Stopping SBA Services 

You can stop and start SBA services as described in the procedure below. 

 

To start and stop services: 

1. 

Select the 

Tools

 menu tab, and then select the 'Start or Stop Service' check box; the 

Start and Stop Service page appears: 

Figure  11-88: Start and Stop Service Page 

 

2. 

Stop or Start the following services: 

 

Front-End Server 

 

Mediation Server 

 

Replica Replicator Agent 

 

Logging Service Agent 

3. 

Select one of the following actions as required: 

 

Start All

: Starts the services on the SBA 

 

Stop All

: Stops the services on the SBA 

 

Restart Server

: Restarts the server 

 

Shutdown Server:

 Shuts down the server 

 

 

Summary of Contents for Mediant 1000B SBA

Page 1: ...Version 6 8 April 2016 Document LTRT 40111 SBA Installation and Maintenance Manual Mediant 1000B SBA for Microsoft Lync Server Microsoft Lync Server Survivable Branch Appliance Mediant 1000B SBA...

Page 2: ......

Page 3: ...ce 39 6 2 Connecting to LAN with Port Pair Redundancy 41 6 3 Connecting to FXS Interfaces 43 6 4 Connecting to ISDN BRI Interfaces 44 6 4 1 Connecting to BRI Lines 44 6 4 2 Connecting the PSTN Fallbac...

Page 4: ...ecurity 121 11 15 1 Apply No Policy 121 11 15 2 Apply Default Security Template 123 11 15 3 Apply User Defined Security Template 126 11 16Step 16 Optional Remote Control 129 11 17Step 17 Optional SNMP...

Page 5: ...grading the SBA Components 191 24 Upgrading MSFT and CU System Components 193 25 Upgrading the Management Interface 197 26 Upgrading using the SBA ProConnect 201 Upgrading and Recovering the SBA Image...

Page 6: ...Windows Update Policy 258 A 6 Firewall Rules 258 A 6 1 Default SBA Internal Firewall Rules 258 A 6 2 SBA Network Firewall Settings 276 B Running Anti Virus Software 279 C Upgrading Hardware 281 C 1 V...

Page 7: ...4 Maintenance Actions Reset Gateway 50 Figure 7 5 Physical Ports Settings Page 51 Figure 8 1 New Object Computer Dialog Box 55 Figure 8 2 RTCUniversalReadOnlyAdmins 56 Figure 9 1 Menu Path to Topology...

Page 8: ...d 97 Figure 11 29 Device Preparation Reboot Message Box 98 Figure 11 30 Device Preparation Completed Successfully 98 Figure 11 31 Cs Database installation Screen 99 Figure 11 32 Cs Database Installati...

Page 9: ...up Setup Completed 136 Figure 11 86 Complete Setup Completed Successfully 137 Figure 11 87 Home Page 138 Figure 11 88 Start and Stop Service Page 139 Figure 11 89 Logs Screen Displaying Logged Events...

Page 10: ...for Serial Communication 223 Figure 30 7 Cabling OSN3 to PC for Serial Communication 223 Figure 30 8 Windows Loading Files 224 Figure 30 9 SAC Started 224 Figure 30 10 SAC Initialized 225 Figure 30 1...

Page 11: ...LEDs Description 33 Table 5 7 Gigabit Ethernet Interface RJ 45 Connector Pinouts 35 Table 5 8 RS 232 Serial Cable Connector Pinouts 35 Table 5 9 HDMX Module LED Description 36 Table 7 1 Physical Port...

Page 12: ...Installation Maintenance Manual 12 Document LTRT 40111 Mediant 1000B SBA This page is left intentionally blank...

Page 13: ...N SmartTAP VMAS VoIPerfect VoIPerfectHD Your Gateway To VoIP 3GX VocaNOM and CloudBond 365 are trademarks or registered trademarks of AudioCodes Limited All other products or trademarks are property o...

Page 14: ...Installation Maintenance Manual 14 Document LTRT 40111 Mediant 1000B SBA Related Documentation Manual Name Mediant 1000B SBA Quick Guide...

Page 15: ...voice services to branch users during a WAN outage a branch office survivability solution the Survivable Branch Appliance SBA application is hosted on the OSN Server platform running on AudioCodes Me...

Page 16: ...aintenance Manual 16 Document LTRT 40111 Mediant 1000B SBA Figure 1 1 SBA Home Page Additional AudioCodes Applications Link New SBA Image Figure 1 2 SBA Home Page Additional AudioCodes Applications Li...

Page 17: ...stallation Maintenance Manual 1 Introduction Version 6 8 17 Microsoft Lync Server The figure below illustrates typical SBA branch office deployment scenarios Figure 1 3 Typical Branch Office Deploymen...

Page 18: ...Maintenance Manual 18 Document LTRT 40111 Mediant 1000B SBA A summary of the steps required to setup the SBA environment is shown in the figure below Figure 1 4 Summary of Steps for Installing and Con...

Page 19: ...s Cable mini HDMI to HDMI 1 5m for monitor connections Cable micro USB to USB 1 5m for serial connections One or two AC power cables depending on customer order USB dongle for SBA software upgrade and...

Page 20: ...Installation Maintenance Manual 20 Document LTRT 40111 Mediant 1000B SBA This page is left intentionally blank...

Page 21: ...and E SBC chassis The chassis s panels are described as follows Front Panel see Section 3 on page 23 Rear Panel see Section 4 on page 25 The AudioCodes SBA is installed on the HDMX disk module and run...

Page 22: ......

Page 23: ...ce of this module depends on the ordered configuration If in the future you need to add such interfaces to your device you can order this module separately TRUNKS TRUNKS E1 TE J1 module Note The prese...

Page 24: ...2 Each power supply unit provides an AC power connector on its rear panel If both Power 1 and Power 2 units are used the load is shared between them This optional load sharing feature enables power f...

Page 25: ...1 Protective earthing screw 2 ESD Electrostatic Discharge ESD socket 3 100 240V 1A Dual AC Power Supply Entries 4 OSN3B or OSN4 OSN3B or OSN4 AMC module Note OSN3 module is no longer available for pur...

Page 26: ...Installation Maintenance Manual 26 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 27: ...ty shortens boot up time and increases the mean time between failures MTBF This enhanced Mediant 1000B SBA ES enables customers to run third party IT software for example anti virus and monitoring age...

Page 28: ...cribed in the subsequent table Figure 5 1 OSN3B and OSN4 Module Ports Table 5 1 OSN3B and OSN4 Module Port Description Item Label Description 1 USB 2 0 port 2 Two RJ 45 ports for Gigabit Ethernet The...

Page 29: ...OSN3B and OSN4 module LEDs are shown in the figure below and described in the subsequent table Figure 5 2 OSN3B and OSN4 Module LEDs Table 5 3 OSN3B and OSN4 Module LEDs Description Item Color State...

Page 30: ...n Off 10Base T connection if LED 3 is active 5 Blue Flashing Module undergoing shutdown sequence when handle is pulled out to first extraction position or module had been inserted and handle is still...

Page 31: ...described in the table below Table 5 4 HDMI Type D Connector Pinouts Pin Signal 3 TMDS Data2 4 TMDS Data2 Shield 5 TMDS Data2 6 TMDS Data1 7 TMDS Data1 Shield 8 TMDS Data1 9 TMDS Data0 10 TMDS Data0 S...

Page 32: ...the SBA with the OSN3 module 5 2 1 Ports Description The OSN3 module is shown below and described in the subsequent table Figure 5 3 OSN3 Module Ports Table 5 5 OSN3 Module Port Description Item Label...

Page 33: ...a processor over temperature above 125 C and as a result the module shuts down Off Normal operation 3 2 Red On When lit during boot up indicates clock failure Flashing Chipset over temperature above 1...

Page 34: ...s slot 7 Red On Hardware failure supplied voltage is not within normal operating range ensure CRMX is installed in chassis Flashing Upgrade in progress Off Normal operation 8 SPEED Green On 100Base TX...

Page 35: ...ctor Pinouts Pin 100Base Tx 1000Base T I O Signal Signal Function 1 O Tx I O BI_DA 2 0 Tx I O BI_DA 3 I Rx I O BI_DB 4 I O BI_DC 5 I O BI_DC 6 I Rx I O BI_DB 7 I O BI_DD 8 I O BI_DD 5 2 4 Serial Cable...

Page 36: ...be ordered with dual hard disk drives i e two HDMX modules The HDMX module is available as either an HDD drive or as an SSD drive The HDMX module is shown below and described in the subsequent table F...

Page 37: ...Part II Setting up the Mediant 1000B PSTN Gateway This part describes how to cable the Mediant 1000B PSTN gateway and how to connect it to the IP network...

Page 38: ......

Page 39: ...e The procedure below describes how to ground the device Protective Earthing The equipment is classified as Class I EN 60950 and UL 60950 and must be earthed at all times using an equipment earthing c...

Page 40: ...Installation Maintenance Manual 40 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 41: ...tandby LAN port If your deployment requires additional ethernet ports you can order the optional SWX module which provides four Ethernet ports Note The SWX module is an optional customer orderable ite...

Page 42: ...t on the CRMX or SWX module Figure 6 4 Connecting to LAN 2 Connect the other end of the cable to the LAN 3 For 1 1 LAN protection repeat Steps 1 and 2 for the standby port but connect it to another ne...

Page 43: ...nsure that FXS ports are connected to the appropriate external devices otherwise damage to the device may occur The FXS ports are considered as TNV 2 Note The FXS module is a customer ordered item Thi...

Page 44: ...ble only if your device is installed with such a module To connect to BRI lines 1 Connect the BRI cable to the device s BRI RJ 45 port 2 Connect the other end of the cable to your ISDN telephone or PB...

Page 45: ...e Port 3 III to Port 4 IIII of the same BRI module For example if a PBX trunk is connected to Port 1 and the PSTN network is connected to Port 2 when PSTN Fallback is activated calls from the PBX are...

Page 46: ...lectrical shock and fire use a 26 AWG min wire to connect T1 or E1 ports to the PSTN Note The TRUNKS module is a customer ordered item This section is applicable only if your device is installed with...

Page 47: ...irectly to the PSTN through Port 2 To connect the digital trunk interfaces for 1 1 PSTN Fallback 1 Connect Trunk 1 to a PBX 2 On the same TRUNKS module connect Trunk 2 to the PSTN Figure 6 9 Cabling P...

Page 48: ...e device s rear panel The dual power option provides the device with power redundancy If both power units are used for load sharing failure protection redundancy ensure that you connect each power sup...

Page 49: ...ngs 7 1 Initial Access to the PSTN Gateway Before you can configure the PSTN Gateway you need to access its Web interface using the default VoIP Management LAN IP address as described in below To init...

Page 50: ...ection 7 3 on page 51 2 Configure a LAN network address so that it corresponds to your network IP addressing scheme and configure the physical LAN port pair in the Multiple Interface Table page Config...

Page 51: ...fferent physical ports is not accessible to one another The only connection between them can be established by cross connecting them with media streams a VoIP calls For each LAN port you can configure...

Page 52: ...acket without a VLAN otherwise the VLAN ID as defined in the Multiple Interface table takes precedence The valid value range is 1 to 4096 The default is 1 Speed Duplex Defines the speed and duplex mod...

Page 53: ...d at headquarters Add the SBA Device to the Active Directory AD See Chapter 8 on page 55 Create a user account on the AD belonging to the RTCUniversalSBATechnicians group This user performs the SBA de...

Page 54: ......

Page 55: ...and Computers b Add the Survivable Branch Appliance device name to the domain computers right click Computers choose New and then click Computer Figure 8 1 New Object Computer Dialog Box c Click Chan...

Page 56: ...pliance computer name that you created in Step b above and then choose Properties g In the Attributes list set servicePrincipalName to HOST SBA FQDN where SBA FQDN is the FQDN of your Survivable Branc...

Page 57: ...w to add the Survivable Branch Appliance to your topology using Lync Server 2013 Topology Builder This configuration includes the following main steps Defining the branch office see Section 9 1 on pag...

Page 58: ...ine the branch office To create branch sites 1 Start the Lync Server 2013 Topology Builder program a Start menu All Programs Microsoft Lync Server 2013 Lync Server Topology Builder or b Start menu All...

Page 59: ...the Branch Office Topology using Topology Builder Version 6 8 59 Microsoft Lync Server Figure 9 2 Menu Path to Topology Builder Program Lync 2010 The Topology Builder opens as shown in the examples b...

Page 60: ...Download Topology from existing deployment option assuming your Lync Server 2013 or Lync Server 2010 deployment already has a topology and then click OK a dialog box opens prompting you to save the ex...

Page 61: ...ng tool to design your Enterprise Voice topology expand the Branch sites node and then expand the name of the branch site you specified in the tool To modify each section of the branch office right cl...

Page 62: ...g box do the following a In the Name field type the name of the branch site Only this field is required the other fields are optional b In the Description field type a meaningful description of the br...

Page 63: ...he name of the state or region in which the branch site is located c In the Country Region Code field type the two digit calling code for the country in which the branch site is located d Click Next t...

Page 64: ...you configured in the FQDN field must be the same as the FQDN that you configured using the ADSI Edit program in Section 0 on page 39 The following dialog box appears Figure 9 11 Select the Front End...

Page 65: ...r Version 6 8 65 Microsoft Lync Server 10 From the Edge pool drop down list select the Edge pool to be used with this SBA optional and then click Next the following dialog box example screens appear F...

Page 66: ...is configured to resolve the FQDN into this IP address b In the Listening port for IP PSTN Gateway field type the Gateway listening port This must be the same port as configured in the PSTN Gateway as...

Page 67: ...pology Once you have defined the Branch Office as described in the previous section you need to publish this new topology as described below To publish the topology 1 Right click the root of the Lync...

Page 68: ...Maintenance Manual 68 Document LTRT 40111 Mediant 1000B SBA 2 Click Next the following screen appears Figure 9 17 Publish Wizard Complete 3 Verify that all steps display the Success status and then c...

Page 69: ...4 Part IV Setting up the SBA Management Interface This part describes how to connect to the SBA Management interface and to install and configure the SBA...

Page 70: ......

Page 71: ...thods Using the internal NIC the SBA is connected to the network via the gateway SBC Ethernet port and the device s internal switch See below If this option is used only a single network cable is requ...

Page 72: ...to the SBA using the internal NIC 1 Connect the first Ethernet port on the CRMX module on the front panel of the device directly to the network using a straight through Ethernet cable Figure 10 1 Con...

Page 73: ...e and then do one of the following If you have a DHCP server in your network note the IP address assigned to the Ethernet port If you are not using a DHCP server then assign a static IP address to the...

Page 74: ...the Internet Download this driver at http www silabs com products mcu pages usbtouartbridgevcpdrivers aspx 4 Establish a serial communication with the OSN server using a terminal emulation program su...

Page 75: ...e IP address that was determined in Step 6 above The Survivable Branch Appliance Management Interface opens Figure 10 5 Welcome to SBA Screen 10 Log in with the default username Administrator and pass...

Page 76: ...our network environment To initially connect to the SBA using the external NIC 1 Using a network cable connect the PC to the appropriate Ethernet port On the OSN3B OSN4 module connect to Port 1 Figure...

Page 77: ...erface opens Figure 10 9 Welcome to SBA Screen 4 Log in with the default username Administrator and password Pass123 Select the Yes I accept the term and condition checkbox and then click Login the Ho...

Page 78: ...Installation Maintenance Manual 78 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 79: ...on 11 6 on page 96 7 Cs Database Installation See Section 11 7 on page 99 8 Backup See Section 11 8 on page 101 9 Enable Replication See Section 11 9 on page 103 10 Activate Lync See Section 11 10 on...

Page 80: ...menu screens the current CPU of the OSN module is displayed in the background In the Setup pane a list of all the configurable items is displayed Table 11 1 Setup Pane Icon Setup Pane Icon Description...

Page 81: ...ox for those interfaces that you are not using 2 From the drop down list select one of the following NIC interface options External1 Corresponds to one of the physical Ethernet ports on the Mediant 10...

Page 82: ...the disconnected external NIC is labeled Local Area Connection 2 the disconnected internal NIC is labeled Local Area Connection 3 and the connected external NIC is labeled Local Area Connection 4 Note...

Page 83: ...icrosoft Lync Server Figure 11 5 IP Settings Login Again 10 Click OK A new login screen appears 11 Enter the Username Password and then click Login Notes The system logs in with the new IP address Eve...

Page 84: ...ion Maintenance Manual 84 Document LTRT 40111 Mediant 1000B SBA A green check mark is displayed next to the IP Settings option under the Setup tab as shown in the figure below Figure 11 6 IP Settings...

Page 85: ...will then be rebooted After the server reboots the following message appears The SBA server has been rebooted automatically You can then login to the SBA Management Interface Once you join to the Dom...

Page 86: ...e also appears to advise that a re boot is necessary for the setting to take effect Figure 11 8 Reboot Computer after Computer Name Change 4 Click Reboot the SBA server reboots and the following scree...

Page 87: ...ure 11 10 Login Screen 5 Enter your username and password and then click Login to log in once again to the SBA Management Interface the Setup tab appears displaying a green check mark next to the Chan...

Page 88: ...Administrator password 1 Select the Setup tab and then select the Change Admin Password check box the following screen is displayed Figure 11 12 Change Admin Password Screen 2 In the Current Password...

Page 89: ...soft Lync Server Figure 11 13 Change Admin Password Applied Changes 5 Click Next to proceed to the next setup task a green check mark appears next to the Change Admin Password option under the Setup t...

Page 90: ...te and Time option resets the date and time zone To set the date and time 1 Select the Setup tab and then select the Set Date and Time check box the following screen is displayed Figure 11 15 Set Date...

Page 91: ...Operation Completed Successfully message appears on the bottom of the screen 6 Click Apply a notification message box appears Figure 11 17 Set Date and Time Notification Message 7 Click OK the followi...

Page 92: ...Installation Maintenance Manual 92 Document LTRT 40111 Mediant 1000B SBA Figure 11 19 Set Date and Time Completed Successfully...

Page 93: ...after a session timeout When this occurs the login screen appears with the following popup message The SBA server needs to be rebooted Please insert your credentials and click on Login The server wil...

Page 94: ...account that has permission to join the SBA to the domain as configured in Chapter 9 on page 57 4 In the Group name field ensure that the RTCUniversalSBATechnicians value is selected 5 Click Apply a...

Page 95: ...n user check box which is selected by default Figure 11 24 Welcome to SBA 8 Log in with the Domain user username and password and then click Login a green check mark is displayed next to the Join to a...

Page 96: ...popup message The SBA server needs to be rebooted Please insert your credentials and click on Login The server will then be rebooted After the server reboots the following message appears The SBA serv...

Page 97: ...lling and Configuring the SBA Version 6 8 97 Microsoft Lync Server Figure 11 27 Device Preparation Started Figure 11 28 Device Preparation All Components Installed 3 When the installation completes yo...

Page 98: ...ted successfully click Reboot If you wish to review some of the steps refer to the Detailed Log for corrective information rectify the problem and then click Apply to install the remaining components...

Page 99: ...lation The Cs Database installation option installs CsDatabase for Lyss and registrar Note This step is not relevant for Microsoft Lync Server 2010 deployments To install the CsDatabase 1 Select the S...

Page 100: ...000B SBA 2 Click Apply the following screen appears Figure 11 32 Cs Database Installation Applied Successfully A green check mark appears next to the Cs Database option under the Setup tab as shown in...

Page 101: ...up option creates a backup copy of the Central Management Server on the SBA server To create a backup of the Central Management Server 1 Select the Setup tab and then select the Backup check box the f...

Page 102: ...ion Maintenance Manual 102 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Backup option under the Setup tab as shown in the figure below Figure 11 36 Backup Completed Suc...

Page 103: ...Management Server The actual replication is executed after all Lync services have been enabled after Step 12 has been completed see Section 11 12 on page 113 To enable replication 1 Select the Setup...

Page 104: ...nable Replication option under the Setup tab as shown in the figure below Figure 11 39 Enable Replication Completed Successfully Note The replication status may not immiediately display the status Up...

Page 105: ...Installing the required software does not automatically cause the SBA server machine to adopt a new service role instead it must be activated before it actually begins to function in its new role To a...

Page 106: ...ntenance Manual 106 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Activate Lync option under the Setup tab as shown in the figure below Figure 11 42 Activate Lync Comple...

Page 107: ...server and the Central Management Server To install a Certificate Select the Setup tab and then select the Lync Certificate check box the following screen appears Figure 11 43 Lync Certificate Screen...

Page 108: ...ificate radio button Figure 11 44 Request Certificate 2 Requesting a certificate supports Auto enrollment Enter all fields Those fields beginning with a CA prefix are mandatory The correct Certificate...

Page 109: ...uring the SBA Version 6 8 109 Microsoft Lync Server Figure 11 45 Lync Certificate Detailed Log 3 If the CA field is not entered the system creates an enrollment certificate which can be downloaded Fig...

Page 110: ...nrolled Certificate 5 Click the Download Enrolled Certificate link the following screen appears Figure 11 48 Lync Certificate File Download 6 Click Save 7 Once the Enrollment Certificate has been sign...

Page 111: ...tenance Manual 11 Installing and Configuring the SBA Version 6 8 111 Microsoft Lync Server Figure 11 49 Lync Certificate File Upload 8 Click Apply the following screen appears Figure 11 50 Lync Certif...

Page 112: ...Maintenance Manual 112 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Lync Certificate option under the Setup tab as shown in the figure below Figure 11 51 Lync Certific...

Page 113: ...rver 2013 formerly termed Communications Server component that runs as a Windows service To start Lync services 1 Select the Setup tab and then select the Start Lync Services check box the following s...

Page 114: ...ces option under the Setup tab and in the Lync Services information pane all of the Lync Services are shown as Running as shown in the figure below Figure 11 54 Start Lync Services Completed Successfu...

Page 115: ...anual To configure the gateway and run test calls 1 Select the Setup tab and then select the Gateway Configuration check box the following screen appears Figure 11 55 Gateway and Endpoint Configuratio...

Page 116: ...Embedded Telnet Server drop down list select Enable Unsecured c In the Telnet Server TCP Port field ensure that the port used for Telnet is 23 default Figure 11 56 Enabling Telnet 8 Configure PSTN cal...

Page 117: ...lift the handset and confirm that you can hear the DTMFs The following screen appears when you answer the phone Figure 11 58 Test Call Succeeded Note It is recommended to disable Telnet after making t...

Page 118: ...al Built in users for HealthMonitoring have been configured using the following commands New CsHealthMonitoringConfiguration Identity XdsGlobalRelativeIdentity FirstTestUserSipUri String SecondTestUse...

Page 119: ...t Call option the Lync Test Call screen is displayed Figure 11 60 Lync Test Call Screen 2 In the Dial Check Phone Number field enter the PSTN phone number to dial 3 Click Apply to start the test call...

Page 120: ...tenance Manual 120 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Lync Test Call option under the Setup tab as shown in the figure below Figure 11 62 Lync Test Call Compl...

Page 121: ...efault security template to the SBA device Upload a security template Load an administrator defined template to the SBA device Note Once a template is loaded you cannot perform rollback using the SBA...

Page 122: ...enance Manual 122 Document LTRT 40111 Mediant 1000B SBA 2 Select the No Policy skip action check box option and then click Apply the following screen is displayed Figure 11 64 Confirmation Security Po...

Page 123: ...ver 11 15 2 Apply Default Security Template This procedure describes how to apply the default security template To apply the default security template 1 Select the Setup tab and then click the Apply S...

Page 124: ...k Apply the SBA automatically logs out Figure 11 66 System Logout Default Security Template Applied 3 Click OK for the system to log out while running the security template the following screen appear...

Page 125: ...g and Configuring the SBA Version 6 8 125 Microsoft Lync Server 5 Login and then select the Setup tab A green check mark appears next to the Apply Security option as shown in the figure below Figure 1...

Page 126: ...ed security template To apply a user defined security template 1 Select the Setup tab and then select the Apply Security check box the following screen is displayed Figure 11 69 Apply Security Policy...

Page 127: ...hen click Apply the SBA automatically logs out Figure 11 71 System Logout Custom Security Template Applied 4 Click OK for the system to log out while running security template the following screen app...

Page 128: ...n Maintenance Manual 128 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Apply Security option as shown in the figure below Figure 11 73 Custom Security Template Successfu...

Page 129: ...sabled and could only be enabled by configuring the parameter PSRemoting Force in the PowerShell RDP Remote Desktop Protocol The RDP is enabled by default for all SBA versions Note If you are using th...

Page 130: ...ce Manual 130 Document LTRT 40111 Mediant 1000B SBA The following screen is displayed after disabling the Remote Desktop and enabling the Remote Powershell Figure 11 75 Remote Desktop Disabled and Rem...

Page 131: ...up SNMP 1 Select the Tools tab and then select the SNMP Setup check box The SNMP Setup screen is displayed Figure 11 76 SNMP Setup Screen If the SNMP Service is running an adjacent green sign is indic...

Page 132: ...al 132 Document LTRT 40111 Mediant 1000B SBA The following screen is displayed Figure 11 77 SNMP Setup Restart Confirmation 7 Click OK and then click Restart The following screen is displayed Figure 1...

Page 133: ...g the SBA Version 6 8 133 Microsoft Lync Server If the SNMP service is stopped the following screen is displayed Figure 11 79 SNMP Service Started 8 Click Start to start the SNMP service The following...

Page 134: ...1 Mediant 1000B SBA If SNMP service is not installed the following screen is displayed Figure 11 81 SNMP Service is not Installed 9 Click Install to install the SNMP service the following screen is di...

Page 135: ...intenance Manual 11 Installing and Configuring the SBA Version 6 8 135 Microsoft Lync Server 10 Click the Tools tab and then select the SNMP Setup check box the following screen is displayed Figure 11...

Page 136: ...orm the procedure described below to complete the SBA setup To complete SBA setup 1 Log in to the SBA Web wizard if not logged in already 2 Select the Setup tab and then select the Complete Setup chec...

Page 137: ...Installing and Configuring the SBA Version 6 8 137 Microsoft Lync Server A green check mark appears next to the Complete Setup option under the Setup tab as shown in the figure below Figure 11 86 Com...

Page 138: ...operating status of the SBA can be viewed in the Home page This page displays the following Central management store location SBA services status stopped or running CPU and network usages Number of in...

Page 139: ...s menu tab and then select the Start or Stop Service check box the Start and Stop Service page appears Figure 11 88 Start and Stop Service Page 2 Stop or Start the following services Front End Server...

Page 140: ...aying logged events Figure 11 89 Logs Screen Displaying Logged Events 2 To view details of a logged event select the event Figure 11 90 Detailed Log Display 3 To clear the displayed log click the Clea...

Page 141: ...art provides step by step procedures for configuring the PSTN Gateway functionality of the Mediant 1000B SBA located at the branch office The configuration is done through the embedded Web server Web...

Page 142: ......

Page 143: ...latest GA 6 60A SIP firmware Version The PSTN Gateway must be installed with the following Feature Keys MSFT enables working with Microsoft Lync IPSEC MediaEncryption StrongEncryption and EncryptContr...

Page 144: ...Installation Maintenance Manual 144 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 145: ...sends the INVITE to the next Mediation Server located at the datacenter To configure the Mediation Server 1 Open the Proxy Registration page Configuration tab VoIP menu SIP Definitions Proxy Registrat...

Page 146: ...ddress as an FQDN ensure that you configure the DNS server see Section 15 1 2 on page 153 b In the Transport Type drop down list select the Transport Type TLS or TCP for these proxies For more informa...

Page 147: ...W and IP to IP Routing Alternative Routing Reasons Figure 13 3 Reasons for Alternative Routing Page b Under the Tel to IP Reasons group from the Reason 1 drop down list select 503 c Click Submit d Ope...

Page 148: ...Installation Maintenance Manual 148 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 149: ...ty feature and then defining the allowed administrative list IP addresses or FQDNs in the Proxy Set table To allow IP communication only between the PSTN Gateway and Mediation Server 1 Open the Advanc...

Page 150: ...Installation Maintenance Manual 150 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 151: ...or authentication during the TLS handshake with the Mediation Server 15 1 1 Step 1 Enable TLS and Define TLS Port The procedure below describes how to enable TLS and configure the PSTN Gateway ports u...

Page 152: ...arty NTP server This ensures that the PSTN Gateway has the same date and time as the Certification Authority CA discussed later in Section 15 1 on page 151 To configure the NTP server 1 Open the Appli...

Page 153: ...tion Server is configured with an FQDN in which case the DNS is used to resolve it into an IP address To configure the DNS servers 1 Open the IP Settings page Configuration tab VoIP menu Network IP Se...

Page 154: ...ay if required when using certificates for TLS see Section 15 1 5 To configure the SIP gateway name 1 Open the Proxy Registration page Configuration tab VoIP menu SIP Definitions Proxy Registration Fi...

Page 155: ...ngs In the TLS Version field choose the TLS 1 0 only from the drop down list Use TLS version 1 0 only AudioCodes recommends implementing only TLS to avoid flaws in SSL Figure 15 5 Configuring TLS vers...

Page 156: ...lder for Lync Server 2013 see Chapter 9 on page 57 7 Copy the CSR from the line BEGIN CERTIFICATE to END CERTIFICATE REQUEST to a text file such as Notepad and then save it to a folder on your compute...

Page 157: ...Transport Type Version 6 8 157 Microsoft Lync Server Figure 15 8 Request a Certificate Page 10 Click advanced certificate request and then click Next Figure 15 9 Advanced Certificate Request Page 11...

Page 158: ...d Request field 13 From the Certificate Template drop down list select Web Server 14 Click Submit Figure 15 11 Certificate Issued Page 15 Select the Base 64 encoded option for encoding and then click...

Page 159: ...les from your computer group click the Browse button corresponding to the Send Device Certificate field navigate to the gateway cer certificate file that you saved on your computer above and then clic...

Page 160: ...diant 1000B SBA Figure 15 14 Importing Root Certificate into Trusted Certificates Store 23 Click OK the certificate is loaded to the device and listed in the Trusted Certificates store 24 Reset the E...

Page 161: ...SIP transport type between the PSTN Gateway and the Mediation Server To set SIP transport type to TCP 1 Open the SIP General Parameters page Configuration tab VoIP menu SIP Definitions General Parame...

Page 162: ...Installation Maintenance Manual 162 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 163: ...The PSTN Gateway initiates encrypted calls but if negotiation of the cipher suite fails the call is terminated Incoming calls that don t include encryption information are rejected Preferable Single M...

Page 164: ...ion Server is configured to Encryption Optional 4 In the Master Key Identifier MKI Size field enter 1 This configures the size in bytes of the MKI in SRTP Tx packets 5 From the Enable Symmetric MKI Ne...

Page 165: ...abled per coder which is recommended for improving the performance of the Mediation Server The procedure below shows how you can change the default coder To configure the voice coder and silence suppr...

Page 166: ...Installation Maintenance Manual 166 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 167: ...ion comfort noise generation automatic gain control AGC and echo canceller enabled by default Note Silence suppression is configured per coder type as described in Section 0 on page 165 To configure v...

Page 168: ...ay reset see Step 8 below 8 From the Enable AGC drop down list select Enable 9 Click Submit to apply your changes 10 On the toolbar click Burn to save the changes to the PSTN gateway flash memory 11 O...

Page 169: ...ceives an ISDN Progress Alerting and Progress Indicator or Connect message For example if the PSTN Gateway receives ISDN Progress it starts sending RTP packets according to initial negotiation but the...

Page 170: ...ndling The PSTN Gateway opens a voice stream toward the first 18x SIP response that includes an SDP and disregards any 18x response with an SDP received thereafter Figure 19 2 SIP General Parameters P...

Page 171: ...edia Version 6 8 171 Microsoft Lync Server Figure 19 3 Advanced Parameters Page 7 From the Enable Early 183 drop down list select Enable 8 Click Submit to apply your changes 9 On the toolbar click Bur...

Page 172: ...Installation Maintenance Manual 172 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 173: ...ls you need to define different Trunk Groups for the digital trunk and the FXS module To enable the FXS ports and PSTN trunks 1 Open the Trunk Group Table page Configuration tab VoIP menu GW and IP to...

Page 174: ...tion tab VoIP menu GW and IP to IP Trunk Group Trunk Group Settings Figure 20 2 Trunk Group Setting Page 2 For the FXS ports i e Trunk Group 1 from the Channel Select Mode drop down list select By Des...

Page 175: ...to Trunk Group routing rule 1 Open the Inbound IP Routing Table page Configuration tab VoIP menu GW and IP to IP Routing IP to Trunk Group Routing Figure 20 3 Inbound IP Routing Table Page 2 In the f...

Page 176: ...k Settings Figure 20 4 Trunk Settings Page 2 On the top of the page a bar with trunk number icons displays the status of each trunk Grey disabled Green active Yellow RAI alarm Red LOS LOF alarm Blue A...

Page 177: ...tings page see Section 20 4 on page 178 To delete a previously configured trunk set the Protocol Type parameter to None b From the Clock Master drop down list select the trunk s clock source Recovered...

Page 178: ...lly A Law is used for E1 and Mu Law for T1 J1 TDM Bus Clock Source defines the clock source to which the PSTN Gateway synchronizes generate clock from local source Internal or recover clock from PSTN...

Page 179: ...and inbound calls i e calls destined to Lync clients Number manipulation and mapping of NPI TON to SIP messages rules are configured in the following Manipulation tables For Tel to IP calls Destinati...

Page 180: ...gn to denote calls without a calling number Source IP Address Defines the source IP address of the caller This is obtained from the Contact header in the INVITE message Notes This parameter is applica...

Page 181: ...he PreferRouteTable parameter is set to 1 Destination IP Group Defines the IP Group to where the call is sent Notes The value 1 indicates that this field is ignored This parameter is applicable only t...

Page 182: ...select Unknown 0 International 1 National 2 Network Specific 3 Subscriber 4 or Abbreviated 6 The default is Unknown Notes This parameter is applicable only to number manipulation tables for IP to Tel...

Page 183: ...irst five digits and add 9 as a prefix to the remaining number Therefore the PSTN Gateway sends the number 95554321 to the PBX and then the PBX sends the number 5554321 to the PSTN 3 National Calls to...

Page 184: ...erefore the PSTN Gateway sends the number 12063331220 to Lync which relays the call to the Lync client 3 National Calls from a Different Area Code The PSTN user dials the national area code and then a...

Page 185: ...21 Configuring Normalization Rules for E 164 Format Version 6 8 185 Microsoft Lync Server The configuration of the above scenarios is shown in the figure below Figure 21 3 Destination Phone Number Man...

Page 186: ...Installation Maintenance Manual 186 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 187: ...RTP behavior upon rekey mode 1 Open the Admin page by appending the case sensitive suffix AdminPage to the SBC s IP address in your Web browser s URL field e g http 10 15 9 101 AdminPage Figure 22 1 A...

Page 188: ...Installation Maintenance Manual 188 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 189: ...ote For this feature to work an MPM module is required and media channels should be configured according to the number of FXS ports see below To configure the FXS port transfer feature using the re in...

Page 190: ...Installation Maintenance Manual 190 Document LTRT 40111 Mediant 1000B SBA Figure 4 29 IP Media Settings 5 Click Submit...

Page 191: ...Part VI Upgrading the SBA Components This part describes how to upgrade the SBA components...

Page 192: ......

Page 193: ...face The following components can be updated Microsoft system components CU updates The LyncServerUpdateInstaller exe provided by Microsoft installs all of the required Microsoft installation componen...

Page 194: ...oft components are listed in the Installed Components pane 3 In the File to upload field click Browse to select the LyncServerUpdateInstaller exe file to upload and then click Apply The following scre...

Page 195: ...t automatically and the login screen is displayed Figure 24 4 Login Screen after Automatic Log Out 4 Enter your login and password details and if the Terms and Conditions checkbox is displayed select...

Page 196: ...Installation Maintenance Manual 196 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 197: ...ync Server 25 Upgrading the Management Interface This section describes how to update the SBA Management Interface To update the SBA Management Interface 1 Login to the SBA Management Interface 2 Sele...

Page 198: ...25 2 System Update Screen 3 In the File to upload field click Browse to select the file to upload and then click Apply the following screen is displayed Figure 25 3 System Update Message SBA Manageme...

Page 199: ...ut automatically and the login screen is displayed Figure 25 4 Login Screen after Automatic Log Out 4 In the Login screen verify that the new SBA version number is displayed 5 Enter your login and pas...

Page 200: ...Installation Maintenance Manual 200 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 201: ...ir SBA manually Consequently for better servicing of such deployments AudioCodes now offers a new application SBA ProConnect which is a Web Management tool for the purposes of easily installing Micros...

Page 202: ...Installation Maintenance Manual 202 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 203: ...4 Part VII Upgrading and Recovering the SBA Image This part describes how to upgrade the Survivable Branch Appliance SBA software application and how to recover it in case of failure...

Page 204: ......

Page 205: ...branch office and provides PSTN termination if implemented for these clients The SBA Upgrade and Recovery procedure is done using AudioCodes SBA Upgrade and Recovery USB dongle which contains a later...

Page 206: ...Installation Maintenance Manual 206 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 207: ...hard disk If you have recently obtained a later SBA image file version it is recommended to copy it to the USB dongle prior to performing the SBA upgrade and recovery and then delete the old image fr...

Page 208: ...Installation Maintenance Manual 208 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 209: ...t based editor such as Notepad the RecoveryUtil ini file located on the USB dongle 3 Perform the required modifications as described in the subsequent subsections 4 Save and close the file 5 Remove th...

Page 210: ...ecovery automatically without confirmation set the Automatic parameter to 1 as shown below Execution Automatic 1 With this setting the SBA upgrade and recovery starts immediately after the OSN server...

Page 211: ...n size in Megabytes DiskPartitions MainPartitionSize 100000 Notes The recommended main partition size is 100000 i e 100 Gigabytes Ensure that the secondary partition is at least 10 GB as it is used to...

Page 212: ...r upon process completion Execution OnExit 1 Shut down OSN server Set the OnExit parameter to 2 to shut down the OSN server upon process completion Execution OnExit 2 Notes The recommendation for this...

Page 213: ...1 as shown below NetworkCardConfiguration EnableDhcp 1 This is only applicable if you have a DHCP server in your network Manually Static define IP address Set the EnableDhcp to 0 as shown below Networ...

Page 214: ...is located on the USB dongle then see Section 29 9 3 on page 215 to define the directory path to where the image file is located Recovery partition Set Source to 4 as shown below ImageSource Source 4...

Page 215: ...e i e ImageSource Source 3 as defined in Section 29 9 on page 214 then you must define the directory path to where the image file is located This is defined using the DOKsettings DirectoryPath paramet...

Page 216: ...tal running of the SBA upgrade and recovery on your PC If not configured the procedure runs on any system User Confirm MacPrefix 00 45 B1 22 49 B1 You can define several MAC addresses by suffixing the...

Page 217: ...llowing Contact your AudioCodes representative to verify if there are any required updates to the OSN s BIOS Enter the OSN server s BIOS setup and set the highest boot priority to the USB dongle and n...

Page 218: ...OSN4 USB Port Figure 30 2 Plugging USB Dongle into OSN3 USB Port 4 Power off and then power on the Mediant 1000B chassis to boot the OSN server from the USB dongle the SBA upgrade and recovery process...

Page 219: ...ngle from the USB port on the OSN module 7 Power off and then power on the Mediant 1000B to reboot the OSN server the initialization process starts Notes This step may take a while about 10 minutes Wh...

Page 220: ...et the OnExit parameter to 2 so that the OSN server shuts down upon SBA upgrade and recovery completion Execution RecoveryStartType 0 Execution OnExit 2 2 Save and close the RecoveryUtil ini file 3 Co...

Page 221: ...USB port on the USB hub 9 Power off and then power on the Mediant 1000B to reboot the OSN server the initialization process starts Notes This step may take a while about 10 minutes While the Mediant...

Page 222: ...remote server cannot access the network or is not fully functional EMS provides a command line environment for managing a server through the out of band port The capability of redirecting text output...

Page 223: ...t an RJ 45 cable connector not supplied to the RJ 45 serial port of the Mediant 1000B OSN3 and then connect the other end of the cable to the serial port of your PC Figure 30 7 Cabling OSN3 to PC for...

Page 224: ...al window the following message is displayed Windows is loading files as shown in the figure below Figure 30 8 Windows Loading Files In a few moments the special administration console SAC prompt appe...

Page 225: ...ge A new channel has been created is displayed type the following command SAC ch si 0001 where 0001 is the number of the created channel Figure 30 10 SAC Initialized The command console starts When th...

Page 226: ...GoreCover The SBA Recovery and Upgrade process starts and logged messages are displayed in the console When the procedure completes successfully the following logged messages are displayed Figure 30...

Page 227: ...Ethernet port All Network Interface Cards NIC are assigned IP addresses by your enterprise s DHCP server if it exists If you are not using a DHCP server you can assign a static IP address to this NIC...

Page 228: ...ork cable connect the Ethernet port labeled on the OSN3 module to the network Figure 30 16 Connecting to LAN Port on OSN3 Module Rear Panel View 2 If you have an HDMI monitor connected do the followin...

Page 229: ...work note the IP address assigned to the Ethernet LAN port If you are not using a DHCP server then assign a static IP address to the NIC of the Ethernet LAN port c Skip to Step 9 3 Connect your PC to...

Page 230: ...n with OSN using a terminal emulation program such as HyperTerminal with the following port settings Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None 5 Press Enter the Seri...

Page 231: ...etwork cable If you have a DHCP server in your network note the IP address of the relevant Ethernet port If you do not have a DHCP server in your network define the static IP address for the specific...

Page 232: ...Welcome to SBA Screen 10 Log in with the default username Administrator and password Pass123 Select the Yes I accept the term and condition checkbox and then click Login the Home screen appears Figure...

Page 233: ...4 Part VIII Appendices...

Page 234: ......

Page 235: ...WCF and Windows Workflow Foundation WF Application Server Foundation provides the means for delivering managed code applications with seamless user experiences secure communication and the ability to...

Page 236: ...SCW Configuration and Analysis The server can be remotely configured analyzed or rolled back using the Security Configuration Wizard SCW user interface or command line tool Shadow Copies of Shared Fo...

Page 237: ...S Client DNS clients also known as resolvers use the DNS Domain Name System protocol to send queries to DNS Servers to lookup the DNS name of a computer and retrieve information associated with the co...

Page 238: ...ing user interfaces protect your customers personal identity information enable seamless and secure communication and provide the ability to model a range of business processes Local Application Insta...

Page 239: ...Sends logging messages to the logging database when logging is enabled for the Active Directory Rights Management Services role If this service is disabled or stopped when logging is enabled logging...

Page 240: ...If this service is disabled any services that explicitly depend on it will fail to start Manual Background Intelligent Transfer Service Transfers files in the background using idle network bandwidth...

Page 241: ...pplication Manages the configuration and tracking of Component Object Model COM based components If the service is stopped most COM based components will not function properly If this service is disab...

Page 242: ...eceive dynamic IP addresses and DNS updates If this service is disabled any services that explicitly depend on it will fail to start Automatic DHCP Server Performs TCP IP configuration for DHCP client...

Page 243: ...on the local computer will start to see failures Automatic Encrypting File System EFS Provides the core file encryption technology used to store encrypted files on NTFS file system volumes If this se...

Page 244: ...strators for the computer and users through the Group Policy component If this service is stopped or disabled the settings will not be applied and applications and components will not be manageable th...

Page 245: ...anagement and Security Application using its locally available selected network interfaces Automatic Intel R Management and Security Application User Notification Service Intel R Management and Securi...

Page 246: ...nd on it will fail to start Automatic KtmRm for Distributed Transaction Coordinator Coordinates transactions between the Distributed Transaction Coordinator MSDTC and the Kernel Transaction Manager KT...

Page 247: ...e Shadow Copy Provider Manages software based volume shadow copies taken by the Volume Shadow Copy service If this service is stopped software based volume shadow copies cannot be managed If this serv...

Page 248: ...Ethernet connection to the network If this service is disabled any services that explicitly depend on it will fail to start Automatic Network Store Interface Service This service delivers network noti...

Page 249: ...n delivery Automatic Print Spooler Loads files to memory for later printing Automatic Problem Reports and Solutions Control Panel Support This service provides support for viewing sending and deletion...

Page 250: ...System properties control panel item Automatic Remote Desktop Services UserMode Port Redirector Allows the redirection of Printers Drives Ports for RDP connections Manual Remote Desktop Services Conn...

Page 251: ...service is disabled any services that explicitly depend on it will fail to start Automatic Secure Socket Tunneling Protocol Service Provides support for the Secure Socket Tunneling Protocol SSTP to c...

Page 252: ...strongly recommended that you not disable the Software Protection service Automatic Special Administration Console Helper Allows administrators to remotely access a command prompt using Emergency Mana...

Page 253: ...hony devices on the local computer and through the LAN on servers that are also running the service Manual TPM Base Services Enables access to the Trusted Platform Module TPM which provides hardware b...

Page 254: ...color rendering Automatic Windows Driver Foundation User mode Driver Framework Manages user mode driver host processes Manual Windows Error Reporting Service Allows errors to be reported when programs...

Page 255: ...r Automatic Windows Management Instrumentation Provides a common interface and object model to access management information about operating system devices applications and services If this service is...

Page 256: ...notifications to index modified content If the service is stopped or disabled the Explorer will not be able to display virtual folder views of items and search in the Explorer will fall back to item b...

Page 257: ...interfaces If your current wired network deployment enforces 802 1X authentication the DOT3SVC service should be configured to run for establishing Layer 2 connectivity and or providing access to netw...

Page 258: ...ed in the SBA deployment These include the following Default SBA internal firewall rules see below SBA network firewall settings see Section A 6 2 Note Many firewall rules are required for normal SBA...

Page 259: ...Allows DHCP Dynamic Host Configuration Protocol messages for stateful auto configuration UDP Inbound dhcp 68 67 Core Networking Dynamic Host Configuration Protocol DHCP Out Allows DHCP Dynamic Host Co...

Page 260: ...remote LSASS traffic for Group Policy updates TCP TCP Outboun d lsass exe _ _ Core Networking Group Policy NP Out Core Networking Group Policy NP Out TCP Outboun d _ _ 445 Core Networking Group Policy...

Page 261: ...ch is unable to forward the packet for any reason except congestion ICMP_V 6 Inbound _ _ _ Core Networking Multicast Listener Done ICMPv6 In Multicast Listener Done messages inform local routers that...

Page 262: ...p membership ICMP_V 6 Inbound _ _ _ Core Networking Multicast Listener Query ICMPv6 Out An IPv6 multicast capable router uses the Multicast Listener Query message to query a link for multicast group m...

Page 263: ...or in response to a Multicast Listener Query ICMP_V 6 Inbound _ _ _ Core Networking Multicast Listener Report v2 ICMPv6 Out Multicast Listener Report v2 message is used by a listening node to either...

Page 264: ...request ICMP_V 6 Outboun d _ _ _ Core Networking Neighbor Discovery Solicitation ICMPv6 In Neighbor Discovery Solicitations are sent by nodes to discover the link layer address of another on link IPv...

Page 265: ...ng Protocol Keyword ICMP_V6 Direction Inbound Packet Too Big error messages are sent from any node that a packet traverses which is unable to forward the packet because the packet is too large for the...

Page 266: ...n ICMPv6 Out Router Solicitation messages are sent by nodes seeking routers to provide stateless auto configuration ICMP_V 6 Outboun d _ _ _ Core Networking Time Exceeded ICMPv6 In Time Exceeded error...

Page 267: ...ut IGMP messages are sent and received by nodes to create join and depart multicast groups IGMP Outboun d _ _ _ Core Networking IPHTTPS TCP In Inbound TCP rule to allow IPHTTPS tunneling technology to...

Page 268: ..._ _ _ Core Networking Teredo UDP In Inbound UDP rule to allow Teredo edge traversal a technology that provides address assignment and automatic tunneling for unicast IPv6 traffic when an IPv6 IPv4 ho...

Page 269: ...t ICMPv4 Out Echo Request messages are sent as ping requests to other nodes Group File and Printer Sharing ICMP_V 4 Outboun d _ _ _ File and Printer Sharing Echo Request ICMPv6 In Echo Request message...

Page 270: ...rule for File and Printer Sharing to allow NetBIOS Name Resolution UDP 137 UDP Inbound _ 137 _ File and Printer Sharing NB Session In Inbound rule for File and Printer Sharing to allow NetBIOS Session...

Page 271: ...ing to allow Server Message Block transmission and reception via Named Pipes TCP 445 TCP Outboun d _ _ 445 World Wide Web Services HTTP Traffic In An inbound rule to allow HTTP traffic for Internet In...

Page 272: ...ice to be remotely managed over Named Pipes TCP Inbound _ 445 _ Remote Administration RPC Inbound rule for all services to be remotely managed via RPC TCP TCP Inbound _ DynamicRPC _ Remote Administrat...

Page 273: ...Inbound _ 445 _ Remote Event Log Management RPC EPMAP Inbound rule for the RPCSS service to allow RPC TCP traffic for the local Event Log Service TCP Inbound Rpcss RPCEndPoint Mapper _ Windows Firewa...

Page 274: ...vschost 135 _ SCW inbound access firewall rule System TCP Allow inbound access for system using ports 139 445 and protocol TCP TCP Inbound _ 139 445 _ SCW remote access firewall rule System UDP Allow...

Page 275: ...Ports Windows Communication Foundation Net TCP Listener Adapter TCP In An inbound rule for Windows Communicati on Foundation to allow TCP traffic to the Net TCP Listener Adapter TCP 808 TCP Inbound n...

Page 276: ...alized Logging Service Front End Servers SBA 50003 TCP SIP MTLS Centralized Logging Service Front End Servers SBA 5090 TCP SIP MTLS WinFabFederationPort Front End Servers SBA 5091 TCP SIP MTLS WinFabL...

Page 277: ...2 TCP SIP MTLS WinFabClientConnectionP ort SBA Front End Servers 5093 TCP SIP MTLS WinFabIPCPort SBA Front End Servers 5094 TCP SIP MTLS WinFabReplicationPort SBA Director 444 TCP HTTPS Certificate re...

Page 278: ...Installation Maintenance Manual 278 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 279: ...Virus Software When Anti Virus software is run on SBA components ensure that the Antivirus file scanning exclusions are based on the following Microsoft recommendations SBA 2010 https technet microso...

Page 280: ...Installation Maintenance Manual 280 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 281: ...e inserted and extracted without disrupting other non related OSN services running on the device Therefore you can insert and replace the OSN modules without powering down the device C 1 Verifying the...

Page 282: ...AudioCodes sales representative To upgrade to an SBA gateway 1 Remove the new OSN server modules from their ESD shielding packets in which they were shipped 2 Install the HDMX module a Remove the bla...

Page 283: ...ng it along the slot s guide rails until it makes contact with the card edge connector located on the backplane Figure C 2 Installing OSN Module c Push the module s handle until it clicks firmly into...

Page 284: ...pull the HDMX module s handle until you hear the first click sound the handle is now partially pulled out and the module undergoes a shutdown sequence indicated by the slow flashing Hot Swap Blue LED...

Page 285: ...the module undergoes a reset indicated by the Hot Swap Blue LED switching off Figure C 4 OSN Module Reset 5 Reset the SBA account on the Active Directory as shown in the screen example below Figure C...

Page 286: ...o M1KB SBA ES EO 1 Shutdown the SBA server see Section 11 19 2 on page 139 2 Remove the HDMX from Slot 1 a Gently pull the HDMX module s handle until you hear the first click sound the handle is now p...

Page 287: ...ted on the backplane Figure C 6 Replacing HDMX Module b Push the module s handle until it clicks firmly into the slot 5 Insert the new OSN3B or OSN4 module into Slot 2 a Hold the new OSN module in the...

Page 288: ...in the screen example below Figure C 8 Reset SBA Account 7 Install the SBA application on the OSN platform using the supplied USB Upgrade and Recovery dongle see Chapter 30 on page 217 8 Connect to t...

Page 289: ...n sequence indicated by the slow flashing Hot Swap Blue LED on the module b When the LED stops flashing and is constantly lit indicating that the shutdown sequence is complete disconnect any cables th...

Page 290: ...Installation Maintenance Manual 290 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Page 291: ...uration as described in Chapter 11 on page 79 Ensure that the HDMX disk in Slot 8 slave is unallocated without a volume allocated Ensure that the storage capacity of both the HDMX disks is identical e...

Page 292: ...th ES D 3 Configuring RAID 1 The procedure below describes how to configure RAID 1 on the Mediant 1000B SBA Note As this is an uptime solution i e it allows you to plan the installation and keep the S...

Page 293: ...ation Maintenance Manual D Configuring RAID Version 6 8 293 Microsoft Lync Server Figure D 3 Computer Management 3 In the Server Manager navigate to the Disk Management menu option Figure D 4 Disk Man...

Page 294: ...Maintenance Manual 294 Document LTRT 40111 Mediant 1000B SBA 4 Convert the disks to Dynamic by right clicking Disc 0 and then selecting the Convert to Dynamic Disk menu option Figure D 5 Convert to D...

Page 295: ...nc Server 5 Select one or more basic disks to convert to dynamic disks and then click OK Figure D 6 Convert to Dynamic Disk Selection 6 In the Disks to Convert screen click Convert Figure D 7 Disks to...

Page 296: ...nt LTRT 40111 Mediant 1000B SBA 8 Add the Mirror by right clicking Partition C and then select the Add Mirror menu option Figure D 9 Add Mirror 9 Select a location for a mirror of Disk C and then clic...

Page 297: ...sion 6 8 297 Microsoft Lync Server 10 The Add Mirror process appears displaying progress in the Status column Figure D 11 Disk Management Resynching 11 When the process has completed the following scr...

Page 298: ...SBA Installation and Maintenance Manual www audiocodes com www audiocodes com...