Microsoft Lync Server
20.2 Configuring IP-to-Trunk Group Routing
The procedure below describes how to configure an IP-to-Trunk Group routing rule,
whereby all calls to +17326521000 and +17326521001 from the Mediation Server need to
be route to Trunk Group 1 (the internal FXS ports) all other calls from Mediation server
need to be route to Trunk Group 2 (the PRI trunk)
To configure an IP-to-Trunk Group routing rule:
1.
Open the Inbound IP Routing Table page (
Configuration
tab >
VoIP
menu >
GW
and
IP to IP
>
Routing
>
IP to Trunk Group Routing
).
Figure
20-3: Inbound IP Routing Table Page
2.
In the first table entry row, enter the +1732652100[0-1] in the ‘Dest. Phone Prefix’.
3.
In the ‘Trunk Group ID’ field, enter the Trunk Group to where the calls must be routed
(Trunk Group ID 1).
4.
In the second table entry row, enter asterisk sign (*) in the ‘Dest. Phone Prefix’.
5.
In the ‘Trunk Group ID’ field, enter the Trunk Group to where the calls must be routed
(Trunk Group ID 2).
6.
Click
Submit
to apply your changes.
7.
On the toolbar, click
Burn
to save the changes to the PSTN gateway flash memory.
Summary of Contents for Mediant 1000B SBA
Page 2: ......
Page 22: ......
Page 38: ......
Page 54: ......
Page 70: ......
Page 142: ......
Page 191: ...Part VI Upgrading the SBA Components This part describes how to upgrade the SBA components...
Page 192: ......
Page 204: ......
Page 233: ...4 Part VIII Appendices...
Page 234: ......
Page 298: ...SBA Installation and Maintenance Manual www audiocodes com www audiocodes com...