Hardware Installation Manual
6. Hardware Maintenance
MSBR Series
55
Mediant 1000B MSBR
3.
Using the module handle, pull the module out of the slot (see stage 3 in the figure
below).
Figure
6-5: Removing AMC Modules
6.1.6
Replacing I/O Modules on the Front-Panel Slots
This section describes how to replace front-panel modules. The device's I/O modules are
hot-swappable (except for the OSN Server modules and the CRMX module). The physical
replacement of the I/O modules is done together with a software replacement procedure
using the device's Web interface. Once you have 'software-removed' the module, you can
then physically remove the module and replace it with a new module. Once the new module
is inserted in the chassis slot, you then need to 'software-insert' it.
Warnings:
•
Replace the module with the same module type and in the same chassis slot. For
example, a damaged TRUNKS module with two digital spans in Slot 1 must be
replaced with a TRUNKS module with two digital spans in Slot 1.
•
When only one I/O module is housed in the chassis, the software-removal procedure
is not applicable; instead, power down the device, physically replace the module, and
then power up the device.
Note:
For replacing the CRMX module, no software procedure is required (i.e., ignore
steps 2 and 7 in the procedure below).
Summary of Contents for Mediant 1000B
Page 1: ...Hardware Installation Manual Mediant 1000B MSBR Multi Service Business Router SIP Protocol ...
Page 2: ......
Page 12: ...Hardware Installation Manual 12 Document LTRT 40881 Mediant 1000B MSBR Reader s Notes ...
Page 14: ...Hardware Installation Manual 14 Document LTRT 40881 Mediant 1000B MSBR Reader s Notes ...
Page 34: ...Hardware Installation Manual 34 Document LTRT 40881 Mediant 1000B MSBR Reader s Notes ...
Page 70: ...Hardware Installation Manual www audiocodes com ...