SIP User's Manual
820
Document #: LTRT-12804
Mediant 800 MSBG
Parameter
Description
Polarity (Current) Reversal for Call Release (Analog Interfaces) Parameters
Web: Enable Polarity Reversal
EMS: Enable Reversal Polarity
[EnableReversalPolarity]
Enables the polarity reversal feature for call release.
[0]
Disable = Disable the polarity reversal service (default).
[1]
Enable = Enable the polarity reversal service.
If the polarity reversal service is enabled, the FXS interface
changes the line polarity on call answer and then changes it
back on call release.
The FXO interface sends a 200 OK response when polarity
reversal signal is detected (applicable only to one-stage
dialing) and releases a call when a second polarity reversal
signal is detected.
Note:
This parameter can also be configured per Tel Profile,
using the TelProfile parameter.
Web/EMS: Enable Current
Disconnect
[EnableCurrentDisconnect]
Enables call release upon detection of a Current Disconnect
signal.
[0]
Disable = Disable the current disconnect service
(default).
[1]
Enable = Enable the current disconnect service.
If the current disconnect service is enabled:
The FXO releases a call when a current disconnect signal
is detected on its port.
The FXS interface generates a 'Current Disconnect Pulse'
after a call is released from IP.
The current disconnect duration is configured by the
CurrentDisconnectDuration parameter. The current disconnect
threshold (FXO only) is configured by the
CurrentDisconnectDefaultThreshold parameter. The frequency
at which the analog line voltage is sampled is configured by
the TimeToSampleAnalogLineVoltage parameter.
Note:
This parameter can also be configured per Tel Profile,
using the TelProfile parameter.
EMS: Polarity Reversal Type
[PolarityReversalType]
Defines the voltage change slope during polarity reversal or
wink.
[0]
= Soft reverse polarity (default).
[1]
= Hard reverse polarity.
Notes:
This parameter is applicable only to FXS interfaces.
Some Caller ID signals use reversal polarity and/or Wink
signals. In these cases, it is recommended to set the
parameter PolarityReversalType to 1 (Hard).
For this parameter to take effect, a device reset is required.
Summary of Contents for Mediant 800 MSBG
Page 2: ......
Page 366: ...SIP User s Manual 366 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 372: ...SIP User s Manual 372 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 390: ...SIP User s Manual 390 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 404: ...SIP User s Manual 404 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 616: ...SIP User s Manual 616 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 636: ...SIP User s Manual 636 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 652: ...SIP User s Manual 652 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 886: ...SIP User s Manual 886 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...