SIP User's Manual
334
Document #: LTRT-12804
Mediant 800 MSBG
3.4.1.1.1 Resetting the Device
The 'Maintenance Actions' page allows you to remotely reset the device. In addition, before
resetting the device, you can choose the following options:
Save the device's current configuration to the device's flash memory (non-volatile).
Perform a graceful shutdown, i.e., device reset starts only after a user-defined time
(i.e., timeout) or after no more active traffic exists (the earliest thereof).
Notes:
•
Throughout the Web interface, parameters preceded by the lightning
symbol are not applied on-the-fly and require that you reset the device for
them to take effect.
•
When you modify parameters that require a device reset, once you click
the
Submit
button in the relevant page, the toolbar displays the word
"Reset" (see ''Toolbar'' on page
) to indicate that a device reset is
required.
•
Upon reboot, the device restores the settings from its configuration file.
However, if reboot attempts fail three times consecutively, the device
resets the configuration file by restoring factory defaults before
attempting to reboot.
¾
To reset the device:
1.
Open the 'Maintenance Actions' page (see ''Maintenance Actions'' on page
2.
Under the 'Reset Configuration' group, from the 'Burn To FLASH' drop-down list,
select one of the following options:
•
'Yes': The device's current configuration is saved (
burned
) to the flash memory
prior to reset (default).
•
'No': Resets the device without saving the current configuration to flash (discards
all unsaved modifications).
3.
Under the 'Reset Configuration' group, from the 'Graceful Option' drop-down list,
select one of the following options:
•
'Yes': Reset starts only after the user-defined time in the 'Shutdown Timeout' field
(see Step 4) expires or after no more active traffic exists (the earliest thereof). In
addition, no new traffic is accepted.
•
'No': Reset starts regardless of traffic, and any existing traffic is terminated at
once.
4.
In the 'Shutdown Timeout' field (relevant only if the 'Graceful Option' in the previous
step is set to 'Yes'), enter the time after which the device resets. Note that if no traffic
exists and the time has not yet expired, the device resets.
Summary of Contents for Mediant 800 MSBG
Page 2: ......
Page 366: ...SIP User s Manual 366 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 372: ...SIP User s Manual 372 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 390: ...SIP User s Manual 390 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 404: ...SIP User s Manual 404 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 616: ...SIP User s Manual 616 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 636: ...SIP User s Manual 636 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 652: ...SIP User s Manual 652 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 886: ...SIP User s Manual 886 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...