CHAPTER 7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm
acBoardEvResettingBoard
Web interface or
SNMP
required.
The alarm remains at Critical severity
level until the device completes the
reboot. A Clear trap is not sent.
Software Upgrade Alarm
Table 7-19: acSWUpgradeAlarm
Alarm
acSWUpgradeAlarm
OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.70
Description
The alarm is sent when an error occurs during the software upgrade
process.
Default
Severity
Major
Alarms
Source
System#0
Event Type
processingErrorAlarm
Probable
Cause
softwareProgramError
Severity
Condition
Text
Corrective Action
Major
Software
upgrade
errors
"SW upgrade error: Firmware burning
failed. Startup system from
BootP/TFTP."
Start up the
system from
BootP/TFTP.
Call Resources Alarm
Table 7-20: acBoardCallResourcesAlarm
Alarm
acBoardCallResourcesAlarm
OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.8
Description
The alarm is sent when no free channels are available.
Note:
To enable this alarm, the Remote Alarm Indication (RAI) mechanism
must be activated, by configuring the [EnableRAI] parameter to [1].
- 117 -