CHAPTER 7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm
acNTPServerStatusAlarm
Protocol (NTP) server.
its IP address is
configured
incorrectly in the
device).
Minor
No communication
to NTP server after
the time was already
set once.
-
-
Ethernet Link Alarm
Table 7-37: acBoardEthernetLinkAlarm
Alarm
acBoardEthernetLinkAlarm
OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.10
Description
The alarm is sent when an Ethernet link(s) is down. The alarm is
sent regardless of the number of ports configured in an Ethernet
Group; as soon as an Ethernet port (link) goes down, the alarm is
sent.
Default Severity
Critical
Source Varbind Text
Board#<n>/EthernetLink#0 (where n is the slot number)
This trap relates to the Ethernet Link Module (the #0 numbering
doesn't apply to the physical Ethernet link).
Event Type
equipmentAlarm
Probable Cause
underlyingResourceUnavailable (56)
Severity
Condition
Text
Corrective
Action
Minor
Ethernet Group
with two Ethernet
ports and only one
is down.
"Ethernet link alarm.
LAN port number <n> link
is down"
(where
n
is the port
number)
1.
Ensure
that the
Ethernet
cables are
plugged
into the
chassis.
2.
Check the
- 141 -