Installation & Operation Manual
100
Document # LTRT-92224
Mediant 8000
16.2
Mounting the Chassis on a Rack
The Mediant 8000 is provided with mounting flanges on either side of the front of the
chassis, appropriate for standard 19-inch racks.
Rack Mount Safety Instructions (UL)
Note:
When mounting the chassis on a rack, be sure to implement the following
Safety instructions:
•
Elevated Operating Ambient
- If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
•
Maintain Air Flow
- Installation of the equipment in a rack should be such that
the amount of air flow required for safe operation on the equipment is not
compromised.
•
Mechanical Loading
- Mounting of the equipment in the rack should be such
that a hazardous condition is not caused due to uneven mechanical loading.
•
Circuit Overloading
- Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing
this concern.
•
Reliable Earthing
- Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g., use of power strips.)
To mount the chassis on a 19-inch rack:
1.
Grasp the handles on either side of the chassis as well as on the base of the
chassis (this requires two people, one on each side of the carton, grasping the
handle and base on that side). Lift it and fit it onto the rack.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...