Version 6.6
153
October 2014
Installation & Operation Manual
21. Software Installation and Basic Configuration
21.3
Starting Mediant 8000 Software
Mediant 8000 software is automatically started after both SC boards are rebooted.
In the default configuration, the SC board in Slot 1 operates as the Active SC board
and performs all maintenance and configuration tasks, while the SC board in Slot 2
operates as the Standby SC board and provides redundancy in case of a failure of the
SC board in Slot 1.
To verify that Mediant 8000 software is up and running on specific SC board:
1.
Connect to the CLI interface on the specific SC board. For more information, refer
to 'Command Line Interface' on page
2.
Login as a regular
CLI
user (e.g.
acladmin
). For more information, refer to
'Logging into Command Line Interface' on page
3.
At the prompt, type
tools sc p
command. A list of SC software processes
indicates that software is up and running.
client241::~#
tools sc p
LIST OF SC SOFTWARE PROCESSES
29510 tg_watch /Project/bin/exe/tg_watchdog
2185 tg_radiu tg_radius
2184 tg_xfer tg_xfer
2183 tg_syslo tg_syslog
2181 tg_core tg_core
2180 tg_tftp tg_tftp
2179 tg_bootp tg_bootp
2178 tg_tpncp tg_tpncpif
2177 tg_sat tg_sat
2176 tg_hbg tg_hbg
2175 tg_hbm tg_hbm
If the SC software is not running, repeat the Mediant 8000 software installation or
basic re-configuration.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...