32.1.1.2
V5.2 Link Status and Maintenance Actions
The V5.2 Interface uses an additional attribute –
Link Operational State
– to indicate
its precise status. The valid values are:
Operational – link is "in service"
Failed
– service is not provided due to some communication error with the far-end
Blocked – service is not provided due to
Block
maintenance request by local
user
Blocked and Failed
–
service is not provided due to both
Block
maintenance
request by local user and a communication error with the far-end
The following maintenance actions are supported on V5.2 Links:
Add / Remove
– adds/removes V5.2 Link
Unlock / Lock
– adds/removes the configuration of the corresponding V5.2
Interface to/from the corresponding Media Gateway board (note that it's not
enough to
Unlock
the V5.2 Link to bring it to service – you must also use
In
Service
action on the corresponding V5.2 Interface)
Block / Unblock
– temporarily stops/starts the service on the corresponding V5.2
Link; if user port is busy (in call), the
Block
action is deferred until the port goes
on-hook; block/unblock actions may also be performed by the soft-switch
Link ID Check
– initiates the link identification check that ensures that there is no
mismatch between the ends of the link; the link's
Link ID Check Status
attribute
is updated accordingly. In addition to the manual initiation (by user), the
identification check is automatically performed on a V5.2 link by either peer at
startup time or after the link recovers from a physical failure.
32.1.1.3
V5.2 User Ports Status
The Mediant 8000 maintains the current V5.2 User Ports configuration in an auxiliary
file named
SlotX_V52_FILE.csv
. The file can be found in auxiliary files repository
(refer to 'Auxiliary Files Repository' on page
) and may be downloaded to your PC
and opened in a text or CSV editor to view the current V5.2 User Ports configuration.
To download the V5.2 User Ports Configuration File:
1.
Click
to access the Media Gateway status screen.
2.
In the Navigation pane, select
Management
Files
;
the Files list is displayed.
3.
Find an auxiliary file that represents the current V5.2 User Ports configuration on
the specific Media Gateway board (it is named
SlotX_V52_FILE.csv
, where X is
the slot number,
and its file type is "V5 Ports Configuration").
4.
Right-click on the auxiliary file and choose
Download File
action.
5.
Choose the location where to download the file (either on your PC or on a file
server) and press
OK
.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...