Version 6.6
413
October 2014
Installation & Operation Manual
34. Performance Measurements
7.
Unlock the Threshold Alarm to activate it.
Figure
34-10: Threshold Alarms Parameters Screen
Table
34-1: PM Threshold Alarm Settings
Parameter Name
Type
Provisioning
Type
Description
Threshold MO
Enum.
Online
Defines the MO to which the threshold is
applied.
MG – threshold is applied to all PM
instances (e.g. in case of a History PM
parameter on Media GatewayMedia
Gateway boards, threshold is applied to all
boards)
Board#x – threshold is applied to PM
instances on a specific Media Gateway
board only.
High Threshold
Counter64
Online
Defines the high threshold value. When
the PM value exceeds the high threshold,
the corresponding Threshold Alarm is
raised.