38-15: SS7 Routeset Properties
Parameter Name
Type
Provisioning
Type
Description
SS7 Route Set
Name
String
Up to 20 chars.
Offline_create
The textual, User-defined name for the
SS7 Routeset, enabling it to be identified
intuitively and easily.
Destination PC
String
Up to 20 chars.
Offline_create
Defines the
point code
of the
destination
signaling
node with which this routeset
connects. It can be specified in numeric
(e.g., 15) or X-Y-Z (e.g., 0-1-1) formats.
The ANSI point code uses 24-bits. It
consists of three octets – network, cluster
and member. An octet is a 8-bit byte which
can contain any value between 0 and 255.
The ITU point code uses 14 bits. It is a
pure binary number that may be stated in
terms of zone (3 bits), area/network (8 bits)
and signaling point identification (3 bits)
numbers.
The China point code uses 24-bits and is
incompatible with both ANSI and ITU
networks.
Route Mask
Integer
0-255
Online
Defines the mask used to select the SS7
Route / Linkset on the basis of the field
SLS/SLC.
Table
38-16: SS7 Linkset Link Properties
Parameter Name
Type
Provisioning
Type
Description
Board ID
Integer
0-19
Offline_create
Defines the ID (slot number) of the Media
Gateway board where the SS7 Data Link
is defined.
SS7 Link ID
Integer
0-32
Offline_create
Defines the ID of the SS7 Data Link.
MTP3 SLS/SLC
Integer
0-15
Offline_create
Defines the SLS/SLC number for this SS7
signaling link, for MTP3 outgoing link
selection.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...