Installation & Operation Manual
496
Document # LTRT-92224
Mediant 8000
Parameter Name
Type
Provisioning Type
Description
OPC 1
String
Up to 20
chars.
Online
Defines the 1
st
filter Originating Point
Code. MTP3 messages that originate at
a specific point code will be associated
with this M3UA Routing Context. An
empty value means that the filter is
deactivated.
Can be specified in numeric (e.g. 15) or
X-Y-Z (e.g. 0-1-1) formats.
ANSI point code uses 24-bits. It consists
of three octets - network, cluster and
member octet. An octet is a 8-bit byte
which can contain any value between 0
and 255.
ITU point code uses 14 bits. It is a pure
binary number that can be stated in
terms of zone (3 bits), area/network (8
bits) and signaling point identification (3
bits) numbers.
China point code uses 24-bits and is
incompatible with both ANSI and ITU
networks.
OPC 2
String
Up to 20
chars.
Online
Defines 2
nd
filter Originating Point Code.
MTP3 messages that originate at
specific point code will be associated
with this M3UA Routing Context. An
empty value means that the filter is
deactivated.
OPC 3
String
Up to 20
chars.
Online
Defines 3
rd
filter Originating Point Code.
MTP3 messages that originate at a
specific point code will be associated
with this M3UA Routing Context. An
empty value means that the filter is
deactivated.
OPC 4
String
Up to 20
chars.
Online
Defines 4
th
filter Originating Point Code.
MTP3 messages that originate at a
specific point code will be associated
with this M3UA Routing Context. An
empty value means that the filter is
deactivated.
Service Indicator 1
Enum
none,0-15
Online
Defines the 1
st
filter Service Indicator.
MTP3 messages that match a specific
SI will be associated with this M3UA
Routing Context. The value 'none'
means that the filter is deactivated.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...