Installation & Operation Manual
92
Document # LTRT-92224
Mediant 8000
15.2
Cables
The following cables are required for proper Mediant 8000 installation.
Note :
Some of the cables described in this section are not supplied with the
system and should be provided by the customer.
Table
15-2: Cabling Requirement
Item
Requirement
Power Cables
8 AWG or lower DC power cables are needed to power the Mediant
8000.
Earthing Cables
4 AWG or better copper cables are required for earthing Mediant
8000. Earthing cable length must not exceed 3 feet (1 meter).
RS-232 Cables
RS-232 cables are used for connecting to the RS-232 Console
Terminal on SC boards and starting up Media Gateway software.
Mediant 8000 is supplied with a standard RS-232 cable. However
ensure that your Terminal Console (or PC) has a matching RS-232
port.
Ethernet Cables
CAT 5 Gigabit Ethernet copper cables are required for connecting
the Mediant 8000 to the IP network.
At least two CAT 5 cables are required - one for each Ethernet
Switch board. More cables are needed if interface separation is
implemented .
PSTN Cables
Depending on the supplied configuration, one of the following
cables are required for connecting Mediant 8000 to the PSTN
equipment:
STM-1/OC-3 cables (for TP-6310):
Twin fiber optic cables with Dual-LC optical connectors are used for
connecting each STM-1/OC-3 interface on TP-6310 board with
PSTN equipment. These cables should be as specified in GR-253-
CORE. Length is determined by the customer.
Small Factor Optical transceivers (SFP) modules are supplied with
Mediant 8000.
T3 cables (for TP-6310 boards):
T3 cables are used for connecting each T3 interface on the TP-
6310 board with PSTN equipment. T3 cables must use an
unshielded mini-SMB female connector MOLEX PN: 73396-0010
(or equivalent) on one side; and male connector MOLEX PN:
73100-0255 (or equivalent) on the other side.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...