OWNER’S MANUAL
CHIMERA SIGNATURE
POWER
CONDITIONER
MAKING CONNECTIONS
1.
Put the hydraulic breaker in the OFF position
Ensure that hydraulic breaker (6) is turned off before start to connect
your Chimera Signature power conditioner.
2.
Plug the power cable in the 32A NEUTRIK powerCON input (1)
3.
Ensure all system electronic components are in the OFF position
4.
Plug each system component into an available outlet
Start with the outlet nearest to the incoming power line with the
power amps; follow with the preamp and other analog components;
and at last with all the digital components in the farthest outlets.
5.
Plug each system component into central ground point
6.
Plug the power cable to the wall outlet
7.
Put the hydraulic breaker in the ON position
Turn on the hydraulic breaker (6). If the breaker trips automatically
right after you turned it on read the “Troubleshooting” section.
Chimera Signature power cable
Chimera Signature requires a 32A NEUTRIK powerCON terminated power
cable. We have supplied a high-end power cord with the Chimera Signature.
However, many users may wish to use after-market AC power cords available
from many cable manufacturers. Only use power cables rated for 20-Amps
of continuous current.
Power-up sequence
WARNING:
Serious damage to internal circuitry can occur if improperly wired or unapproved AC
power cables are used. Do NOT operate this unit with a cable with ground pin disconnected. Also
if the unit is plugged into a voltage different from the range listed on the rear panel, it will result in
serious damage and will void the warranty.