background image

128-6994

1 of 8

Model AX-200

Installation Manual

Note:

 When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver’s door pin

switch in order to begin the passive arming sequence.

RF Programmable Features:

Feature Selection

1 Chirp

2 Chirps

3 Chirps

4 Chirps

Default

1st Door L/UL

1 Sec.

3.5 Sec.

1 Sec L, Dbl. U/L

1 Sec.

2nd Accy Lock

Auto Lock On

Auto Lock Off

Auto Lock Off

3rd Accy. UL

Auto UL Dr.

Auto UL All

Auto UL Off

Auto UL Off

4th Passive Locks

Passive

Active

Active

5th Passive/Active Arm

Passive Arm

Active Arm

Active Arm

6th Voltage Sense

Voltage Sense

Hardwire

Hardwire

7th Siren/Horn

Siren/Horn

Siren Only

Horn Only

Siren/Horn

8th Horn Chirp

10mS

16mS

30mS

16mS

9th Override Method

Custom Code

Valet

Valet

10th Two Step Unlock

On

Off

Off

11th Chirp Delete From Tx On

Off

Off

To program these selectable features;

Action

System Response

Turn ignition on No response
Press and release the valet switch 3 times

1 Chirp - LED 1 flash

Within 3 seconds, turn ignition Off

Short chirp, then long chirp

First

Then On

1 chirp = 1 second door locks

Press transmitter Lock button to change

2 chirps = 3.5 second door locks

Press transmitter Lock button to change

3 chirps = 1 sec. lock, dbl 1 sec. unlock

or

Second

Press and release the valet switch

2 chirps = auto locks off

Press transmitter Lock button to change

1 chirp = auto locks on

or

Third

Press  and release the valet switch

3 chirps = auto unlock off

Press transmitter Lock button to change

1 chirp = auto unlock dr.

Press transmitter Lock button to change

2 chirps = auto unlock all

o r

Fourth

Press and release the valet switch

2 chirps = active locks

Press transmitter Lock button to change

1 chirp = passive locks

o r

Fifth

Press and release the valet switch

2 chirps = active arming

Press transmitter Lock button to change

1 chirp = passive arming

o r

Sixth

Press and release the valet switch

2 chirps = hardwire

Press transmitter Lock button to change

1 chirp = voltage sense

o r

Seventh

Press and release the valet switch

1 chirp = siren and horn output

Press transmitter Lock button to change

2 chirps = siren output only

Press transmitter lock button to change

3 chirps = horn output only

SELECTABLE FEATURES

Summary of Contents for 1286994

Page 1: ...turn ignition Off Short chirp then long chirp First Then On 1 chirp 1 second door locks Press transmitter Lock button to change 2 chirps 3 5 second door locks Press transmitter Lock button to change...

Page 2: ...s within the engine compartment To prevent water retention the front or sounding end of the siren must be pointed downward when mounted Mount the siren to the selected location using the screws and br...

Page 3: ...itry will be Moving this connection point to the fuse panel will increase the sensi tivity and connecting to the courtesy lamp fuse in the vehicle will provide maximum sensitivity of the voltage sense...

Page 4: ...does not recommend using the Orange wire to interrupt anything but the starting circuit of the vehicle Brown w Black Trace Wire LOW CURRENT NEGATIVE HORN OUTPUT 300mAMAX CURRENT This wire provides a 3...

Page 5: ...all other doors 3 Wire Ground Switched Single Step Door Locks In this application the green wire provides a ground pulse during arming or the pulsed ground lock output Connect the green wire to the wi...

Page 6: ...ion if this is the case in the vehicle you are working on connect the remaining terminal 87 to a fused 12 volt source In the rare instance that the vehicle door lock unlock motor legs rest at 12 volts...

Page 7: ...ks and heavy equipment To decrease sensitivity turn the adjustment screw counter clock wise Wire Dressing Always wrap the alarm wires in convoluted tubing or with a spiral wrap of electrical tape Secu...

Page 8: ...128 6994 8 of 8 2003 Audiovox Electronic Corp 150 Marcus Blvd Hauppauge N Y 11788 128 6994...