background image

6

PLUG-IN CONNECTIONS AND COMPLETING THE INSTALLATION:
Now that all the other components have been installed, and most of the main connections completed, it is
time to finish connecting the remaining plug-in components and completing the installation.  Even though
these are plug-in connections, and the plugs have been shaped such that they cannot be plugged in
wrong, please read and follow the instructions below for each connection to make certain each component
is properly installed.

DASH MOUNTED LED

2-PIN White Plug w/2 Wires; Red & Blue
The Red & Blue wires in the 2-PIN mini white connector control the anode and cathode of the dash
mounted LED.  Route the twin lead Red and Blue wires from the LED to the control unit and plug the two
pin connector into the mating white mini connector shell of the control module.  Do not force the connector,
it will only plug in one way.

OPTIONAL SHOCK SENSOR
4-PIN White Plug w/4 Wires; Red, Black, Blue, & Green
The Red (+12 volt), Black (ground), Blue (pre-detect) and Green (full trigger when armed) wires loaded
into the white connector shell are the inputs/outputs of the shock sensor.  Route the 4 wire harness from
the shock sensor location to the EX-6000 Control Module and plug the 4-PIN white connector into the
mating 4-PIN connector.

VALET/PROGRAM/MANUAL OVERRIDE SWITCH
2-PIN Blue Plug w/2 Wires; Black & Gray
The Black & Gray wires in the 2-PIN blue connector are the ground supply and Valet/Program input of the
EX-6000 unit.  When the Gray wire is grounded, under certain conditions, the unit will enter the valet
mode.  When the Gray wire is sequentially grounded under other conditions, the unit will enter the various
program modes.  Route the Black and Grey wires from the Valet/Program/Manual Override switch to the
EX-6000 unit and plug the blue 2-PIN connector into the mating blue connector shell of the EX-6000
control module.  Do not force the connector, it will only plug in one way.  Note:  Please refer to the section;
"Programming System Features" shown later in this installation guide to learn the operation of the valet/
program/manual override switch.

POWER DOOR LOCK HARNESS
2-PIN White Plug w/2 Wires; Red & Green
The connection of the power door lock/unlock wires has already been explained.  Route the Red and
Green wires to the EX-6000 unit and plug the white 2-PIN connector into the mating white two pin con-
nector shell of the EX-6000 control module.  Do not force the connector, it will only plug in one way.

TRANSMITTER PROGRAMMING:

The transmitters supplied with the EX-6000 are pre-programmed at the factory to provide the following function:

Lock/unlock Button, pressed and released quickly =

Arm/Disarm (Lock & Unlock) w/Siren Chirps

Lock/unlock Button, pressed for ~ 1 second

=

Arm/Disarm (Lock & Unlock) w/o Siren Chirps

Lock/unlock Button, pressed for ~ 3 seconds

=

Engage/Disengage Panic Mode

Option 1, pressed for ~ 3 seconds

=

Channel 2 Output

If you desire to have the transmitters operate differently from this factory configuration, please refer to the
separate Transmitter Programming Guide that came with the EX-6000 system.

PROGRAMMING FEATURES:

There are five (5) Programmable Features on the EX-6000 system.  Study the list below, keeping in mind
the features and their defaults, (how it comes programmed from the factory), and decide how best to
program the EX-6000 for your particular installation.

Summary of Contents for Exclusive EX-6000

Page 1: ... Vehicles With 12 Volt Negative Ground Electrical Systems Only Kit Contents 1 EX 6000 Control Module 2 Channel Code Learning Receiver 2 Three Button Transmitters 1 Multi Pin Input Output Harness 1 Two Pin Door Lock Harness 1 Two Pin LED Indicator 1 Two Pin Valet Programming Switch 1 Single Tone Siren 1 Installation Manual 1 Operator s Manual 1 Limited Warranty ...

Page 2: ...e compartment for maximum sound distribution Before securing the siren check behind your chosen location to assure that the mounting screws will not penetrate any factory wiring or fluid lines Secure the siren mounting bracket using 8 screws by first using the mounting bracket as a template scribe or mark the three bracket mounting holes Drill the three marked holes using a 1 8 drill bit than moun...

Page 3: ... harness These fuseholders each hold a separate ATC fuse one 5AMP and one 15AMP This RED wire must be connected to a constant power wire at the vehicle s ignition switch harness or fusebox Most vehicles have at least one battery source wire supplying power to the ignition switch Locate a constant power wire or power taping point either at the vehicle s ignition switch harness or fuseblock This wir...

Page 4: ...series type You may chose to use any of the diodes in this series with the 1N4003 and 1N4007 being the most common types The diodes must be installed with careful regard for their direction of current flow Note This wire will be shunted when remote control channel 2 is accessed trunk release This wire will remain shunted all the while there is ground present and for 5 seconds after the ground is r...

Page 5: ...ule Determine the door lock circuit of the vehicle you are working on and wire according to the diagrams shown WIRING FOR GROUND PULSE DOOR LOCK CIRCUITS This is a system commonly used on most import vehicle s factory door lock unlock systems and with a few domestic vehicles which employ factory keyless entry systems In this application the Red wire serves as the Lock output providing a ground pul...

Page 6: ...y wire is sequentially grounded under other conditions the unit will enter the various program modes Route the Black and Grey wires from the Valet Program Manual Override switch to the EX 6000 unit and plug the blue 2 PIN connector into the mating blue connector shell of the EX 6000 control module Do not force the connector it will only plug in one way Note Please refer to the section Programming ...

Page 7: ...important to note that when you first enter the Programming Mode you are automatically positioned to adjust the First Programmable Feature and that the Valet Program Manual Override Switch allows you to toggle from there through each of the four more programmable features However it will not allow you to return to any feature once you have toggled past it Should you accidentally toggle past the fe...

Page 8: ... to the next feature OR Toggle the Valet Program Manual Override Switch once to Advance to the next feature OR Turn the Ignition Switch OFFto exit the Programming Mode NOTE If you accidentallytoggled past the feature you intended to adjust you must exit and re enter the mode OR Toggle the Valet Program Manual Override Switch once to Advance to the next feature OR Toggle the Valet Program Manual Ov...

Page 9: ...9 2002 Audiovox Electronics Corporation 128 6187 ...

Reviews: