background image

KEYLESS ENTRY ALARM UPGRADE MODULE

INSTALLATION INSTRUCTIONS

PRE - INSTALLATION NOTES :

STAND ALONE PASSIVE ALARM

When installing the APS-30 as a stand alone passive alarm system, the dip switches

must

be set as follows;

Dip Switch # 1 = ON
Dip Switch # 2 = ON
Dip Switch # 3 = OFF
Dip Switch # 4 = OFF
Dip Switch # 5 = OFF
Dip Switch # 6 = OFF

PASSIVE / ACTIVE ARMING SELECTION : DIP SWITCH # 1

This alarm can be programmed to operate as either a " PASSIVE " or " ACTIVE " arming security system.

As a passive arming system, the alarm will automatically arm 30 seconds after the ignition key is turned off, one door is opened, then
all doors are closed. Additionally, if a door has been left opened, or if one of the trigger zones is defective, the system will always arm
10 minutes after the ignition key has been turned off, and ignore the defective trigger zone.

As an active arming system, the alarm will arm only when the vehicle’s doors have been locked using the existing OEM Keyless Entry
Transmitter.

The system is shipped from the factory in the active arming mode, and to select the passive arming mode, move dip switch # 1 to the "
ON " position.

1 OR 2 WIRE DISARM INPUT SELECTION : DIP SWITCH # 2

This alarm can be programmed for either 1 wire or 2 wire disarm operation.

Many OEM keyless entry systems use on - board door unlock relays, which usually results in the ability to disarm the aftermarket security
upgrademodulebyunlockingthedoorsusingthedoorpanelunlockswitch.Wiringthesystemfor2wiredisarmwilleliminatethisproblem.
The system is shipped from the factory in the 2 wire disarm mode, and to select the 1 wire disarm mode, move dip switch # 2 to the "
ON " position.

HORN OR SIREN OUTPUT SELECTION : DIP SWITCH # 3

This system provides an output that should be used to drive the siren, but can be programmed to pulse the vehicle's horn.
When utilizing the horn, an additional relay is required.

Caution: on many vehicles the factory horn is not designed

forcontinuoususe,anditisrecommendedthatthesirenisusedforthesevehicles.Checktoseeifthehorninthevehicle
is the same part that is used in a vehicle with the factory installed security system.

DIP SWITCH SETTINGS

1
2
3
4
5
6

PASSIVE ARMING

1 WIRE DISARM

HORN MODE

INSTANT TRIGGER

-

ARM INPUT

VOLTAGE SENSE

ON

OFF

ACTIVE ARMING

2 WIRE DISARM

SIREN MODE

ENTRY DELAY

+

ARM INPUT

HARDWIRE

Model APS-30

Summary of Contents for Keyless Entry Alarm Upgrade Module APS-30

Page 1: ...select the passive arming mode move dip switch 1 to the ON position 1 OR 2 WIRE DISARM INPUT SELECTION DIP SWITCH 2 This alarm can be programmed for either 1 wire or 2 wire disarm operation ManyOEMkeylessentrysystemsuseon boarddoorunlockrelays whichusuallyresultsintheabilitytodisarmtheaftermarketsecurity upgrademodulebyunlockingthedoorsusingthedoorpanelunlockswitch Wiringthesystemfor2wiredisarmwil...

Page 2: ...DIP SWITCH 5 This alarm can be programmed to accept either a positive or negative arm input signal This allows for proper installation into vehicles using 3 wire ground 3 wire 12 volt and 5 wire alternating door locking systems In the negative mode the system will operate with keyless entry systems providing a ground output to the power door lock circuit Inthepositivemode thesystemwilloperatewithk...

Page 3: ...l not damage any existing components as it passes through the panel Drill a 1 4 diameter hole and pass the red and blue wires from the L E D through the hole from the front of the panel Firmly press the body of the L E D into the hole until fully seated VALET SWITCH Select a mounting location for the valet switch that is easily accessible to the driver of the vehicle The switch does not have to be...

Page 4: ...the vehicle s parking lights WHITE w BLACK TRACE WIRE POSITIVE OUTPUT TO SIREN OR HORN This is a 3 A 12 VDC transistorized switched or pulsed output when triggered see Dip Switch 3 In the siren mode connect this wire to the positive wire of the siren Secure the black ground wire of the siren to chassis ground In the horn mode connect this wire to terminal 85 of an external relay connect terminal 8...

Page 5: ...ectiontooptionalgroundoutputtriggerdevices such as motion and or shock impact sensors DARK GREEN WIRE INSTANT TRIGGER ZONE 2 This is an instant on ground trigger wire It must be connected to the previously installed hood and trunk pin switches 4PINCONNECTOR IMPORTANT When installing the APS 30 as a stand alone passive security system the RED wire in this connector must be connected to a 12 VDC swi...

Page 6: ...LOCK RELAY WIRING THE ARM DISARM INPUTS IN VEHICLES WITHOUT 2 STEP UNLOCK GREEN WIRE or ARM INPUT Connectthiswiretothedriver sdoorlockmotorwire whichwillreceive 12voltswhenthedoorsarelocked using the door panel switch or the remote transmitter RED WIRE DISARM INPUT 1 Connect this wire to the unlock output wire from the OEM keyless entry control module Refer to the diagram RED w BLACK TRACE WIRE DI...