Printed in Taiwan
Audiovox Corp., 150 Marcus Blvd. Hauppauge, N.Y. 11788
Form No.
128-4515
+
FACTORY
REMOTEKEYLESS
ENTRY MODULE
+
TYPICAL 2-STEP DIAGRAM
TYPICAL ONE-STEP DIAGRAM
+
FACTORY
REMOTEKEYLESS
ENTRY MODULE
ALL
UNLOCK
OUTPUT
ALL
LOCK
OUTPUT
ALL
UNLOCK
OUTPUT
ALL
LOCK
OUTPUT
CONNECT
"DISARM INPUT #1"
HERE.
CONNECT
"DISARM INPUT #2"
HERE.
UNLOCK
LOCK
LOCK
UNLOCK
+
+
CONNECT
"ARM" INPUT
HERE
FACTORY
DOOR LOCK
RELAYS
LEFT REAR
D/L MOTOR
RIGHT REAR
D/L MOTOR
RIGHT FRONT
D/L MOTOR
DRIVER'S
D/L MOTOR
DRIVER'S
D/L MOTOR
RIGHT FRONT
D/L MOTOR
RIGHT REAR
D/L MOTOR
LEFT REAR
D/L MOTOR
CONNECT
"ARM" INPUT
HERE
UNLOCK
LOCK
UNLOCK
DOOR PANEL
LOCK / UNLOCK
SWITCH
DOOR PANEL
LOCK / UNLOCK
SWITCH
LOCK
CONNECT
"DISARM INPUT #2"
TO CHASSIS GROUND
FACTORY
DOOR LOCK RELAYS
CONNECT "DISARM
INPUT #1" HERE
THEN CUT THE WIRE
AND ADD A DIODE,
AS SHOWN.
IF GROUND SWITCHED
DOOR LOCKS - TURN
DIODE TO FACE INTO THE
KEYLESS MODULE AND
CONNECT DISARM #2 TO
+12 VOLTS
DRIVER'S
DOOR UNLOCK
RELAY
WIRING THE ARM / DISARM INPUTS IN VEHICLES WITHOUT 2 STEP UNLOCK
GREEN WIRE :
( + or - ) ARM INPUT
Connect this wire to the driver's door lock motor wire, which will r12 volts when the doors are locked
using the door panel switch or the remote transmitter.
RED WIRE :
DISARM INPUT # 1
Connect this wire to the unlock output wire from the OEM keyless entry control module. Refer to the
diagram..
RED w/ BLACK TRACE WIRE :
DISARM INPUT # 2
If the Red wire is switched to +12 volts when the doors are unlocked, connect the Red w/Black Trace wire
to ground.
If the Red wire is switched to ground when the doors are unlocked, connect the Red w/Black Trace wire
to +12 volts.
BLUE WIRE :
(+) TRUNK TRIGGER SHUNT INPUT
This wire will determine if the vehicle’s trunk has been opened using the OEM transmitter, and stop the alarm from triggering when
the transmitter is used.
Connect this wire to the + 12 volt trunk release output from the OEM Keyless Entry module.
VALET SWITCH :
Plug the 2 pin connector from the valet switch into the mating 2 pin connector on the control module.
L.E.D. :
Plug the 2 pin connector from the L.E.D. into the mating 2 pin connector on the control module.