Option 1: Control lift & screen with wall mounted switch or external relay.

How to connect:

Connect a cable to end-switch UP and end-switch DOWN to the NO 
(normally opened) side of the switches.

Connect the DOWN switch to command DOWN of the screen control box

Connect UP wires to the UP of the screen control.

Explanation: The end switches of the lift will activate the screen control.
Use the standard external control connection of the Audipack lift to control 
both systems. Use an optional Audipack RF remote (261436) set if required.

Note:

The end switches will permanant activate the screen control.
The screen will be activated when the lift is set to

“service 

position

”.

230 VAC

NO - Down

NO - UP

Reviews: