background image

Installation instruction Rota-Kit series 
 

 

The Rota-Kit is available in various version and are suitable for directing projectors to 
projection screens and flat screens towards public. With the 4 free programmable 
positions (within 350 degrees), the projector or flat screen can be pointed at any desired 
direction.  
To mount projectors or flat screen  one of the option above mentioned are needed. 
Lock the option firmly with the screw and alan key. This prevent unwanted rotation. 
 
Accuracy of positioning: 

When the projection screens are beeing installed before the Rota-Kit, the following tolerance 
can occur. The tolerance is caused by the resolution of the digital measurement of the Rota-
Kit and the position of the screen. Ones the positions are set, the acuuracy of positioning will 
be very high. See below the tolerance measured out in a scheme.   

 

Projection tolerance when pointing on a : 
Projection distance 

Possible dislocation 
at positioning 

Tolerance afther 
placement 

5 meters 

10 mm 

+/- 1 mm 

10 meters 

15 mm 

+/- 2 mm 

15 meters 

20 mm 

+/- 4 mm 

20 meters 

25 mm 

+/- 8 mm 

 

The tolerance is the difference between the programmed position and the actual reached position compare with the already installed 
screen. The shown tolerances are indicated and can only be less then  shown. 
 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for Rota-Kit P2630

Page 1: ...Mounting instructions Rota Kit series Copyright Audipack version 31 03 09 ...

Page 2: ... are beeing installed before the Rota Kit the following tolerance can occur The tolerance is caused by the resolution of the digital measurement of the Rota Kit and the position of the screen Ones the positions are set the acuuracy of positioning will be very high See below the tolerance measured out in a scheme Projection tolerance when pointing on a Projection distance Possible dislocation at po...

Page 3: ...a scheme Projection tolerance when repositioning Projection distance Tolerance after placement 5 meters 1 mm 10 meters 2 mm 15 meters 4mm 20 meters 8mm The tolerance is the difference between the programmed position and the actual reached position The shown tolerances are indicated and can only be less then shown 1 When mounting the Rota Kit to the ceiling be aware that the Rota Kit is installed l...

Page 4: ... the inserts with an allen key 3 Connect the Rota Kit according the scheme below Function Wire combinaton Key board position Store C S Rotate Left C L Rotate Right C R Go to position 1 C 1 Go to position 2 C 2 Go to position 3 C 3 Go to position 4 C 4 C common Use only potential free contact closures to make the connection Max control cable length aprox 30 meters Minimum shielded cable thickness 0...

Page 5: ...rees away from it s 0 position homing position This can be done by using the wired controll or press on the key board Set the temporarely first position Press button and within 1 second button Aim the projector by loosening the ball joint When the correct position is found lock the ball joint firmly Tip Always programm the latest position firt The programm the first position In this way the progra...

Page 6: ...arts 4b Mount the monitor bracket to the flat screen Mount this assembly to the rota kit Connect the power adapter to the Rota Kit The Rota Kit will automatically go to it s 0 position Refer 4a for programming the positions Using the Rota Kit with a remote controll When the Rota Kit is used with the optional 260218 IR or 260219 RF remote please refer to the installation manual of the print set In ...

Page 7: ...uctions on the wiring diagram Use for each position a separate relay do not use 1 relay for 2 positions Use the below listed Audiapck remote controls for wirless remote 1 x 260218 Infra red remote for 2 positions 1 x 261227 Infra red remote for 4 positions 1 x 260219 RF remote for 2 positions 1 x 261228 RF remote for 4 positions ...

Page 8: ... The control panel must be installed or positioned in the way that the operator has constant visual contact with the Rota Kit during it s travel C The Rota Kit is not suitable for rotating persons D It is allowed to mount 1 piece of equipment keeping the allowed max load of the Rota Kit in mind E When more equipment needs to be installed the equipment must be assembled in a way that they are mount...

Page 9: ...e the black Rota Kit cover Beware of the flat cable Confirm the position of both connectors motor and sensor Clean them if necessary with contact spray Reinstall the cover Test the programming The Rota Kit does not find its zero point when the power has been reconnected to the Rota Kit Disconnect the green connector from the Rota Kit to exclude possible wirering problems between Rota Kit and contr...

Page 10: ...Notes ...

Reviews: