RS-232 registers
29
Returns with the text: “FM is OFF”
19.6
MISCELLANIOUS INSTRUCTIONS
D
=
Switch debug on/off
R<X>
=
Read register <X>
W<X>=<data>
=
Write <data> into register X
V<X>
=
Set PWM motor speed <X> (0 < X > 1023)
K<X>
=
Set motor position in counts (50 < X > 60000)
(ascii letters are not case sensitive)
19.7
REGISTER R1000 [Device Name]
In register “R1000” the device name is stored .
R1000[Enter]
Returns “AUDIPACK DUAL UNIT”