Settings
19
14
Program rotary switch (SW1)
14.1
Precautions
Before changing the program state disconnect the power from the control board.
Set memory positions under load. Place the projector or flat screen before
storing the memory positions.
14.2
Rotary switch positions versus functions
Rotary switch on position “0” = DC motors up to 30VDC without position control
Rotary switch on position “1” = DC motors up to 30VDC, column lifts with intern
limit switches and position control.
Rotary switch on position “2” = DC motors up to 30VDC with external limit
switches and position control, auto homing.
Rotary switch on position “3” = DC motors up to 30VDC with external limit
switches and position control, manual
Rotary switch on position “4” = Single phase AC tube motors with external limit
Switches .
Rotary switch on position “5” = Single phase AC tube motors with external limit
Switches and position control, manual
(4 & 5 not applicable on PCB 261377)