2a.
Ceiling installation:
Install the Audipack ceiling mount to the structural ceiling.
Refer to the installation manual of the ceiling mount to install correctly.
Use ceiling mounts 390061 or 390065 (max. Load per piece 70 Kg).
In a ceiling mounted situation, the thinner lid of the Silencer is mounted
between the projector mount and tube set.
Install the tube set, theninstall the pre-mounted projector mount with lid
to the ceiling mount.
2b.
Ceiling lift installation:
When the Silencer is installed to an Audipack ceiling lift, make sure the
centre point of gravity of the product is in line with the ceiling lift.
An unbalanced assembly will affect the function, and accuracy of the
ceiling lift.
Use all approriate mounting holes for installing the
Silencer to the lift.
Pleas note (when ordering) the way of use of the
Silencer).
Always use the P7010 mounting interface to connect
the Silencer to a lift.
3.
Attach all needed projector cabling and guide the cable in a way that they
do not obstruct airflow or closing the Silencer. For every model the cable
management can change.
4.
The Silencer has a build-in hour-counter. This counter is essential to count
the running hours of the ventilators. After a certain amount of hours the
ventilators should be replced to ensure optimum ventilation.
This is in advantage of the projector running hours.