Modifcations on the single components
C
D
B
E
Insert the supplied 1,5 mH coil
Insert the supplied 10 µF
capacitor
Replace the 4,7
Ω
resistor
originally mounted with the 6,8
Ω
one, supplied with the product.
1. Remove the screws securing the
coil from the bottom of the PCB;
2. Unsolder the coil leads;
3. Unwind the coil with the help of
an LCR meter until the value of
3,3 mH can be measured;
4. Refixe the coil.
Replace the supplied
resistors originally mounted
following the diagram
on page 31 or 33