ARCHITECT AND ENGINEER SPECIFICATIONS

The microphone shall be of the condenser type with a modular threaded 
capsule. The microphone shall be available in a cardioid polar pattern and shall 
have a 3’ or 8’ cable (depending on model) terminating in a mini-XLR female 
connector. The microphone shall have a sensitivity of 4.5 mV /Pa and a nominal 
impedance of 800 ohms at 1 kHz. The microphone shall have a maximum SPL 
level of ≥120 dB and shall be machined out of brass with a length of 25 mm and 
a capsule diameter of 10 mm. The microphone shall be the Audix ADX10.  

OPERATION AND MAINTENANCE 

The ADX10 is designed to plug directly into the bodypack of an Audix  
wireless system. 

Using the ADX10 as a hard wired mic: 

You will need the APS910 or APS911 

phantom power supply. 

APS910 and APS911 phantom power adapters:

 Note that the mini-

XLRf connector at the end of the ADX10 plugs into mini-XLRm side of the 
APS910 or APS911 phantom power adapter. From there, plug a standard 
XLR-XLR microphone cable to complete the connection to the mixing board. 

 

Avoid plugging or unplugging the microphone from a PA system unless the 
channel is muted or the volume of the system turned down. Failure to do so may 
result in a loud  “popping” noise which could seriously damage the speakers in 
the PA system.

Acoustic instruments:

 For violin, the ADX10 may be attached to the collar of 

a shirt pointing out towards the body of the instrument. For guitar, the ADX10 
may be placed beneath the strings (with tape or velcro) or inside the guitar as 
an internal microphone. For udu drums, the ADX10 will fit inside the hole of the 
drum and held in place with clay. For flute see ADX10FLP.

USER TIPS 

Lavalier: 

The ADX10 can be attached to a tie, a lapel, or to fabric by means 

of the supplied alligator style clip. For best results, the microphone should be 
positioned so that the capsule of the microphone is in an upward position and 
4-6 inches from the mouth. Be sure that the round ports on the microphone 
capsule always remain exposed and do not get covered up in any way  
by clothing. 
It is recommended to use the supplied external windscreen to help reduce 
popping and breath noise. 

Further miking techniques may be found at 

www.audixusa.com

.

ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

www.audixusa.com 

503.682.6933 Fax: 503.682.7114 

Audix Corporation 9400 SW Barber St. Wilsonville, OR 97070

ver 3.0 09-16

PRODUCT REGISTRATION: 

Please register your product online at 

www.audixusa.com/docs_12/about/product_registration.shtml

.

SERVICE AND WARRANTY: 

This microphone is under warranty for a period of 3 years to be free of defects in material and workmanship. In the event of a product failure due to materials or 

workmanship, Audix will repair or replace said product at no charge with proof of purchase. Audix does not pay or reimburse shipping costs for warranty repairs or returns. The warranty excludes 
any causes other than manufacturing defects, such as normal wear, abuse, environmental damage, shipping damage or failure to use or maintain the product per the supplied instructions.  No 
Implied Warranties: All implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose are hereby excluded. The liability of Audix, if any, 
for damages relating to allegedly defective products shall be limited to the actual price paid by Dealer for such products and shall in no event include incidental or consequential damages of 
any kind. Should your microphone fail in any way, please contact the Audix Service department at 503.682.6933.  A Return Authorization is required before returning any product. OTHER THAN 
THIS WARRANTY, AUDIX MAKES NO WARRANTIES, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCTS, THE USE OF THE PRODUCTS, THE PERFORMANCE OF THE PRODUCTS. AUDIX SHALL 
NOT BE LIABLE FOR SPECIAL INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SIMILAR DAMAGES ARISING FROM OR BASED ON THE SALE, USE, STORAGE OR DISPOSAL OF THE PRODUCTS, AUDIX’S 
SERVICE WORK, BREACH OF WARRANTY, BREACH OF CONTRACT.  NEGLIGENCE, OR ANY OTHER THEORY OF LIABILITY, EVEN IF AUDIX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 

DIMENSIONS (mm)

SPECIFICATIONS

AD

X10

Transducer Type

Pre-Polarized Condenser

Frequency Response

50 Hz - 18 kHz

Polar Pattern

Cardioid

Output Impedance

800 ohms

Sensitivity

5 mV / Pa @ 1k

Equivalent Noise Level

<29 dB (A-weighted)

Signal to Noise Ratio

>65 dB

Maximum SPL

≥120 dB

Power Requirements

9-52 V phantom

Connector

Shielded 3’ terminating to a 
miniature 3 pin Female XLR 
connector

Polarity

Positive pressure on diaphragm 
produces positive voltage on 
pin 2 relative to pin 3

Materials / Finish

Machined Brass / Black Finish

Weight

21 g / 0.74 oz

Length

25 mm / .98 in