background image

Installation Instructions

Extension Set

COMmander 6000R Xtension

Check the Package Contents

Use the following list to make sure the package contents is complete.

1 Expansion power supply unit, including connecting cable for the base power supply and the 
expansion circuit board

1 Expansion circuit board (10 additional module expansion slots), including connecting cable

1 Bag with Accessories including:

6 x Fastening screws for the expansion circuit board

4 x plastic nipples for the blind panels

4 x collar screws for the blind panels

1 Blind panel 25TE (for 5 module expansion slots)

21 module guide rails (1 rail as spare part)

1 Installation manual (DIN A5)

1 Supplement Conditions of Guarantee, Information Service

Intended Use

The extension set COMmander 6000R Xtension serves to upgrade the COMmander 6000R PBX with 
5 module expansion slots to a COMmander 6000RX PBX with 15 module expansion slots and an 
expansion power supply unit.

You can find further information on the installation site, the PC minimum requirements, the installation 
of the modules, and the operation of the device in the installation and commissioning manual, as well 
as in the operation and configuration manual for the COMmander 6000R/RX (as PDF on the 
Auerswald Mega Disk and as part of the help in the configuration manager of the COMmander 6000R/
RX).

Important:

Improper use may cause, for example, functional restrictions or interference, the 
destruction of the device or, in a worst case scenario, personal injury

If you are still not sure of the intended use of the product after reading the following 
section, please contact your vendor.

Important Information

General limitation of legal responsibility and application

Auerswald products are not designed, manufactured, or intended for use or resale in environments 
requiring fail-safe performance, such as in the operation of life-support systems and/or nuclear 
facilities. Use or sale of our products for these purposes is only allowed with prior written permission 
by Auerswald for each individual incident.

Copyright

Disseminating and reproducing these instructions, as well as using and disclosing the contents, even 
in part, is permitted only with our express permission. Offenders will be subject to claims for damages. 
All rights reserved. 

 Auerswald GmbH & Co. KG, 38162 Cremlingen, 2011

Accessory and Service components

Accessories and service parts can be bought at specialised stores or in the Internet shop distriCOM 
at http://www.districom.de. (Delivery is provided only in Germany and Austria.)

How to contact us

If there are any questions about your Auerswald system, please contact our representatives or distri-
butor in the country of sale. The contact information can be found on the Auerswald web site (Internet 
address: www.auerswald.com).

Technical Data

Operating voltage: 

from the basic unit COMmander 6000R

Power consumption*: 

min. 7.1 W, max. 230 W

Weight: 

approx. 5.400 g (complete system COMmander 6000R incl. 
6000R Xtension without modules)

Safety: CE

* dependent of the extension version of the PBX

Security Advice

 Warning!

Improper handling of the device can result in life-threatening electrical shock.

Only a skilled electrician may open the casing. If necessary, have an authorised dealer 
commission the device.

Only a skilled electrician may perform installation work within an open casing or service work 
using the buttons inside the casing. If necessary, commission an authorised dealer to perform this 
work.

Touching voltage-carrying conductors or telephone connections may cause a life-threatening electric 
shock.

The PBX contains hazardous voltages, even outside of the power supply unit (for instance ringer 
voltages). Work on active, contact-hazardous parts is only permitted after creating a voltage-free 
state.
Working close to active parts is only permitted if these parts are voltage-free or are protected 
against direct contact.

The Power button switches the voltage at the module expansion slots and on the main circuit 
board off. If the system is switched off, a skilled electrician can be commissioned to replace or 
install expansion modules. When installing or replacing a module, only touch the fixing compo-
nents of the front plate where necessary. Do not insert any electrically conductive objects into the 
casing, since hazardous voltages continue to apply in the power supply unit of the system.

Remove any voltage from the device by discharging any capacitors present, if necessary. In the 
case of a malfunction, the electrolytic capacitor for the switch-mode power supply can remained 
charged for a long time even after being turned off.

If available, also disconnect the devices from auxiliary power sources (for example, UPS).

Do not make any structural changes to the device (exception: COMmander 6000R Xtension).

When commissioning a skilled electrician to upgrade a COMmander 6000R PBX with the 
COMmander 6000R Xtension extension set, the power plug must be unplugged by all means 
before starting the assembly. It does not suffice to push the Power button.
Only mount the components in a voltage-free state.

After having a COMmander 6000R with the COMmander 6000R Xtension extension set 
upgraded by a skilled electrician, the safety of the device has to be checked according to BGV A3 
(a German safety directive issued by the Accident Prevention & Insurance Association).

For some installation and maintenance work, it is necessary to open the PBX while it is in 
operation (skilled electrician only). Make sure that the PBX is never left unattended while working 
with an open casing.

Be sure to follow the relevant regulations when handling 230 V system voltage and devices 
attached to the mains.

Only operate the device when the casing is closed.

Only operate the device when it is securely fastened in a 19" rack.

Damaged connection lines as well as damage to the casing and to the PBX can cause life-threatening 
electrical shocks.

Only connect the device connection cable with sockets that are designed for that purpose.

Make sure that the Schuko socket for connecting the PBX is properly connected (according to 
VDE 0100). The power socket must be located near the PBX and be freely accessible at all times.

Replace damaged connection lines immediately.

Use original components and original spare parts only.

Always have a professional carry out repairs immediately. Please contact your skilled electrician 
or the manufacturer directly.

Power surges, which can occur during electrical storms, can cause life-threatening electric shocks 
and may damage or destroy the PBX.

For this reason, do not mount the PBX during an electrical storm. Avoid disconnecting and 
connecting lines during an electrical storm.

Let a skilled electrician lay all the cables inside the building – including the cable to the door 
terminal system.

Protect the devices by installing overvoltage protection.

 Caution!

Unauthorised changes to the device can damage the PBX or breach security and EMC regulations. 
If security-relevant radio services are disturbed, the Federal Network Agency can order decommis-
sioning the device according to §14, section 6, Electromagnetic Compatibility Act.

Always have a professional carry out repairs. Please contact your skilled electrician or the manuf-
acturer directly.

The memory card of the PBX contains data which is necessary for the operation of the PBX. Do 
not remove, mount, or format the memory card. The memory card on the base circuit board 
should only be exchanged in the case of service jobs according to the directives of Auerswald 
service staff.

Exceeding (even temporarily) the threshold values indicated in the technical data can damage or even 
destroy the PBX.

Note the threshold values indicated in the technical data for voltage, electricity, performance, 
ambient temperature and humidity.

Make sure not to cover the fan on the rear side of the casing.

Electrostatic charges can destroy sensitive components.

Divert electrostatic charges from yourself before touching the circuit boards with your hands or 
any tools. To do this, touch a metal object, preferably earthed, e. g. the earthing terminal of the 
PBX or a computer housing.

8

8431

8

02 08/

1

1

Reviews:

Related manuals for COMmander 6000R Xtension