466
COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
Functions
Relays (Actuators)
Switching Authorisation for Switching of Relays On/Off
Proceed as follows:
•
Separately for relays
•
Using the configuration manager
Requirements:
•
Created analogue relay
1. Open the page
Devices > Relays (Actuators)
.
2. Click
Configure
in the line for the corresponding relay.
3. Enter DTMF sequences required by the connected device in the
Switch on
and
Switch off
entry fields. Possible entries:
Switching Authorisation for Switching of Relays On/Off
If the authorisation for switching of relays is enabled, the subscriber in question can switch
relays manually.
Proceed as follows:
•
Separately for subscribers
•
Separately for configurations
•
Using the configuration manager
Note:
As described in the following, the setting is also possible via profiles
(
Subscriber (scr.) > Profiles > Configuration > Configure > Auhtorisa-
tions
). If the check box
Profile-controlled settings
has been selected, the
property set in the right-hand column will apply. For assignment of the profile,
see chapter Settings > Profiles.
1. Open the page
Subscriber (scr.) > Properties > Authorisations
.
2. In the list field at the top, select the subscriber in question by his name or number.
Digits and the characters * and #
The comma ',' character as a pause of half a second